504: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 26: Line 26:
whereas the 504 contains a simple ground referenced vertical amplifier.   
whereas the 504 contains a simple ground referenced vertical amplifier.   
Due to the low bandwidth and need to keep the selling price low,  
Due to the low bandwidth and need to keep the selling price low,  
neither the 503 or 504 include delay lines in the vertical signal path. Both scopes use the same CRTs, the [[T5030]].   
neither the 503 or 504 include delay lines in the vertical signal path.
Both scopes use the same CRTs, the [[T5030]].   


The CRT circuit uses a single [[5642]] to generate the -3000 V cathode voltage.   
The CRT circuit uses a single [[5642]] to generate the -3000 V cathode voltage.   
Line 38: Line 39:
==Pictures==
==Pictures==
<gallery>
<gallery>
File:Tek 504.JPG
Tek 504.JPG
File:Tek-504.jpg
Tek-504.jpg
File:Tek-504-front.jpg
Tek-504-front.jpg
File:Tek-504-right.jpg
Tek-504-right.jpg
File:Tek-504-left.jpg
Tek-504-left.jpg
File:Rm504 white.jpg|RM504
Rm504 white.jpg|RM504
Tek rm504 trace.jpg|RM504 trace
Tek rm504 trace.jpg|RM504 trace
</gallery>
</gallery>


[[Category:Monolithic tube scopes]]
[[Category:Monolithic tube scopes]]

Revision as of 15:21, 3 February 2018

{{{manufacturer}}} 
450 kHz scope
Tektronix 504

Produced from 1960 to 1973

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 504 is a monolithic oscilloscope with a bandwidth of 450 kHz introduced in 1960.

It was introduced at the same time as the 503, and is mechanically and electrically identical, other than the vertical amplifier.

The 504 was also offered in a rack mount version, the RM504.

Specifications

please add

Internals

The 503 incorporates two identical phase matched amplifiers with true differential inputs to support X-Y operation, whereas the 504 contains a simple ground referenced vertical amplifier. Due to the low bandwidth and need to keep the selling price low, neither the 503 or 504 include delay lines in the vertical signal path. Both scopes use the same CRTs, the T5030.

The CRT circuit uses a single 5642 to generate the -3000 V cathode voltage. There is no post-deflection acceleration.

Triggering is done using a multivibrator made of a 6DJ8 tube. The vertical signal path has a 6DJ8 first stage, a BJT second stage, followed by the the output stage. The vertical and horizontal output stages use pairs of 6CB6 tubes.

Pictures