3T77: Difference between revisions
No edit summary |
No edit summary |
||
Line 51: | Line 51: | ||
==Pictures== | ==Pictures== | ||
<gallery> | <gallery> | ||
Tek 3t77 front.JPG|3T77 front | |||
3t77 1.jpg|3T77 | |||
3t77 2.jpg|3T77 | |||
3t77 3.jpg|3T77 | |||
3t77 4.jpg|3T77 | |||
3t77 5.jpg|3T77 | |||
3t77 6.jpg|3T77 | |||
3t77 7.jpg|3T77 | |||
3t77 8.jpg|3T77 | |||
3t77 9.jpg|3T77 | |||
3t77a trig.jpg|3T77A Trigger Board | |||
3t77 trigger schem.png|Trigger schematic | |||
3t77 block diagram.png|Block Diagram | |||
3t77 connector and ps schem.png|Connector and Power Supply | |||
3t77 horizontal amp schem.png|Horizontal Amp Schematic | |||
3t77 staircase schem.png|Staircase Schematic | |||
3t77 fast ramp schem.png|Fast Ramp Schematic | |||
Tek 3t77a front.jpg|3T77A | |||
Tek 3t77a left.jpg|3T77A | |||
Tek 3t77a right.jpg|3T77A | |||
Tek 3t77a triggerboard.jpg|3T77A | |||
Tek 3t77a top.jpg|3T77A | |||
Tek 3t77a rear.jpg|3T77A | |||
</gallery> | </gallery> | ||
Revision as of 17:10, 3 February 2018
Template:Plugin Sidebar 2 The Tektronix 3T77 is a sampling sweep plug-in for 560-series scopes. It was introduced in 1962, along with the 567 and 3S76.
It triggers on either the internal trigger pick-off from the vertical plug-in or from an external trigger signal input. Triggering is faster and more sensitive with an external input.
The 3T77 can operate in any of four modes: external sweep, manual sweep, normal, or single sweep. In external sweep mode, an external control voltage is applied to a BNC connector on the front panel of the 3T77. This voltage determines the X-position of the spot on the CRT and, correspondingly, the delay from the trigger event to the sampling point. Manual mode is the same as external sweep mode, but the control voltage is generated internally based on the position of a potentiometer on the front panel of the 3T77. In normal mode, an internal ramp generator produces the control voltage, repeatedly redrawing the trace on the CRT. In single sweep mode, the internal ramp generator is started by a button on the front panel, makes on horizontal trace, and then waits for the button to be pressed again.
The 3T77 uses 2N976 transistors and 1N3129 tunnel diodes. It uses a 6688 tube in the staircase generator circuit.
Difference of 3T77 and 3T77A
Time-Postiton instead Delay-Knob, with more range of delaying by slow sweep rate. Recovery-Time-Knob can be pulling for HF-sync.
Specifications
please add
Pictures
-
3T77 front
-
3T77
-
3T77
-
3T77
-
3T77
-
3T77
-
3T77
-
3T77
-
3T77
-
3T77
-
3T77A Trigger Board
-
Trigger schematic
-
Block Diagram
-
Connector and Power Supply
-
Horizontal Amp Schematic
-
Staircase Schematic
-
Fast Ramp Schematic
-
3T77A
-
3T77A
-
3T77A
-
3T77A
-
3T77A
-
3T77A