TAP1500: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
The '''Tektronix TAP1500''' is a 1.5 GHz ×10 active probe with a [[TekVPI]] interface. | |||
{{BeginSpecs}} | |||
{{Spec | Bandwidth | DC to >1.5 GHz }} | |||
{{Spec | Risetime | <267 ps }} | |||
{{Spec | Voltage range | ±8 Volts Dynamic Range with ±10 volt offset capability }} | |||
{{Spec | Input impedance | 1 MΩ // <1 pF (10× Attenuation) }} | |||
{{EndSpecs}} | |||
* [http://w140.com/tek_tap1500_instruction_manual.pdf Tektronix TAP1500 Instruction Manual (PDF)] | * [http://w140.com/tek_tap1500_instruction_manual.pdf Tektronix TAP1500 Instruction Manual (PDF)] | ||
[[Category:Active Oscilloscope Probes]] | [[Category:Active Oscilloscope Probes]] | ||
[[Category:TekVPI]] |
Revision as of 02:03, 4 October 2018
The Tektronix TAP1500 is a 1.5 GHz ×10 active probe with a TekVPI interface.
Key Specifications
Bandwidth | DC to >1.5 GHz |
---|---|
Risetime | <267 ps |
Voltage range | ±8 Volts Dynamic Range with ±10 volt offset capability |
Input impedance | 1 MΩ // <1 pF (10× Attenuation) |