Revision as of 15:12, 20 November 2018
The Tektronix T0520 is a CRT used in the 525, 532, 570, and 575. It was originally known as the T52. It has an unaluminized face and is typically operated with 4 kV of total acceleration voltage, e.g., +2300 V on the anode and -1700 V on the cathode.
The T0520 is known as the 5CAP in the EIA system.
154-0093-00 is a T0520 with P1 phosphor, aka T0520-1. 154-0343-00 is a T0520 with P31 phosphor, aka T0520-31.
Specifications
With 4000 V total acceleration voltage:
- horizontal sensitivity: 21 V/cm
- vertical sensitivity: 9.9 V/cm