P6053: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
|||
Line 23: | Line 23: | ||
==Manuals== | ==Manuals== | ||
* [[Media:P6052-P6053-1971-Catalog.pdf|Description of P6052 and P6053 in 1971 Catalog (PDF,OCR)]] | * [[Media:P6052-P6053-1971-Catalog.pdf|Description of P6052 and P6053 in 1971 Catalog (PDF,OCR)]] | ||
* [[Media:P6053.pdf|Tektronix P6053 Manual (PDF)]] | |||
* [[Media:P6053A.pdf|Tektronix P6053A Manual (PDF)]] | |||
* [http://w140.com/P6053b_Rev_Sep_1987g.pdf Tektronix P6053B Manual (September 1987 version, PDF,OCR)] | * [http://w140.com/P6053b_Rev_Sep_1987g.pdf Tektronix P6053B Manual (September 1987 version, PDF,OCR)] | ||
Revision as of 16:18, 20 December 2018
The Tektronix P6053 is a 500 MHz passive ×10 probe with a readout pin and an identification button, intended for 7000-series scopes .
The 6053B is a 200 MHz passive ×10 probe.
Key Specifications
— P6053 — | |
Bandwidth | 500 MHz |
Rise time | ≤0.7 ns |
Cable length | 3.5 ft or 6 ft |
Input impedance | 10 MΩ // 9.5 pF (3.5'), 12 pF (6') |
— P6053B — | |
Bandwidth | 200 MHz (9' model: 115 MHz) |
Maximum input | 500 V DC + peak AC to 3.5 MHz |
Cable length | 3.5 ft, 6 ft, or 9 ft |
Input impedance | 10 MΩ // 10 pF (3.5'), 13 pF (6'), 14 pF (9') |
— Both — | |
Compensation range | 1 MΩ // 15-24 pF |
Manuals
- Description of P6052 and P6053 in 1971 Catalog (PDF,OCR)
- Tektronix P6053 Manual (PDF)
- Tektronix P6053A Manual (PDF)
- Tektronix P6053B Manual (September 1987 version, PDF,OCR)
Accessories
- hook tip (206-0114-00)
- retractable-hook tip (013-0107-00)
- bayonet-ground adapter (013-0085-00)
- minigator clip (344-0046-00)
- probe holder (352-0234-00)
- 3-inch ground lead (175-0848-00)
- 5-inch ground lead (175-0848-01)
- insulating tube (166-0404-01)
- (opt) 017-0076-00 probe tip to GR adapter
- (opt) 013-0084-01 probe tip to BNC adapter