2230: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 24: Line 24:
sister model of [[2220]] and [[2221]].
sister model of [[2220]] and [[2221]].


It features alphanumeric CRT readout of many of the front panel controls. It has both an analog mode and a digital mode.
It has both an analog mode and a digital mode. In the digital storage mode, up to three waveform sets  
In the digital storage mode, up to three waveform sets (CH 1 and/or CH 2)
(CH 1 and/or CH 2) may be stored in a save ref. memory and recalled for display at a later time.
may be stored in a save ref. memory and recalled for display at a later time.


The 2230 has a DB-9 auxiliary connector on the right side providing an external clock input as well as an output for an analog X-Y plotter to make permanent copies of the display. This feature can be accessed through the "Mem select" menu.
The 2230 features alphanumeric CRT readout of many of the front panel controls.
It has a DB-9 auxiliary connector on the right side providing an external clock input as well as an output for an  
analog X-Y plotter to make permanent copies of the display. This feature can be accessed through the "Mem select" menu.


Some Firmware versions have a diagnostics menu with the Tektronix logo and wizard image.  
Some Firmware versions have a diagnostics menu with the Tektronix logo and wizard image.  

Revision as of 05:24, 7 March 2019

{{{manufacturer}}} 
100 MHz portable DSO
please add image

Produced from 1986 to 1989

Manuals

Modifications

(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 2230 is a portable 100 MHz, dual-channel combination analog / digital storage scope, sister model of 2220 and 2221.

It has both an analog mode and a digital mode. In the digital storage mode, up to three waveform sets (CH 1 and/or CH 2) may be stored in a save ref. memory and recalled for display at a later time.

The 2230 features alphanumeric CRT readout of many of the front panel controls. It has a DB-9 auxiliary connector on the right side providing an external clock input as well as an output for an analog X-Y plotter to make permanent copies of the display. This feature can be accessed through the "Mem select" menu.

Some Firmware versions have a diagnostics menu with the Tektronix logo and wizard image.

The Cursor knob is prone to failure. It becomes jittery and will not scroll properly.

Key Specifications

Bandwidth 100 MHz (analog)
Sampling rate 20 MS/s
Record length 1K or 4K samples (single channel), optional 26K
Features
  • Pre/Post-triggering
  • Averaging
  • Dual time base
  • Cursors and readout
  • GPIB option

please add

Links

Pictures