454: Difference between revisions
No edit summary |
No edit summary |
||
Line 12: | Line 12: | ||
*[http://w140.com/454A_Operators_Handbook_1970.pdf Tektronix 454A Operators Handbook (PDF, OCR)] | *[http://w140.com/454A_Operators_Handbook_1970.pdf Tektronix 454A Operators Handbook (PDF, OCR)] | ||
*[[Media:Tek 454 eis no ocr.pdf|Tektronix 454 Engineering Instrument Specification (PDF, needs OCR)]] | *[[Media:Tek 454 eis no ocr.pdf|Tektronix 454 Engineering Instrument Specification (PDF, needs OCR)]] | ||
* [[Media:Tek 454 fcp jan 1968.pdf]] | * [[Media:Tek 454 fcp jan 1968.pdf|Tektronix 454 Factory Calibration Procedure, January 1968 (PDF, needs OCR)]] | ||
}} | }} | ||
Revision as of 07:11, 4 June 2019
The Tektronix 454 is a 150 MHz portable dual-trace scope introduced in March 1967.
It can be seen as an improved 453. The successor 454A was introduced in 1971.
The 454 is the fastest general-purpose Tektronix scope that does not use proprietary hybrid or integrated circuits. It uses a CRT with distributed vertical deflection plates.
Specifications
With the input sensitivity set to 10 mV/div and above, the 454A has a vertical bandwidth of 150 MHz. At 5 mV/div it is 100 MHz, and at 2 mV/div it is 50 MHz.
It is possible to cascade the channel-1 and channel-2 input amplifiers to obtain a sensitivity of 400 μV/div. In that configuration, the vertical bandwidth is 33 MHz.
The 454 weighs 29 pounds and consumes about 130 watts. It has two ±12 V probe power outputs for P6045 probes.
- please add
Internals
The 454 has a 140 ns delay line in the signal path after the input channel switching and before the main vertical amplifier. There is a phase equalizer after the delay line to mitigate the harm done to pulse fidelity by the delay line.
The 454 uses the T4540 CRT.
Links
Pictures
454
-
454 with traces
-
-
'A' intensified during 'B' mode
-
454 with P11-CRT
-
-
-
-
-
-
-
454A
-
454A Front
-
454A Bottom
-
454A Vertical amp
-
454A Top