570: Difference between revisions
Line 41: | Line 41: | ||
==Pictures== | ==Pictures== | ||
=== Early Tektronix 570 === | |||
<gallery> | |||
Tek570-test-setup.jpg | |||
Tek 570 top controls and storage.jpg | |||
</gallery> | |||
===Tektronix 570 Serial Number 5010=== | |||
<gallery> | <gallery> | ||
Tektronix-570-Outside-Front.jpg | Tektronix-570-Outside-Front.jpg | ||
Tektronix-570-Inside-Right.jpg | Tektronix-570-Inside-Right.jpg | ||
Tektronix-570-Inside-Left.jpg | Tektronix-570-Inside-Left.jpg | ||
Line 51: | Line 56: | ||
Tektronix-570-Outside-Front-Close2.jpg | Tektronix-570-Outside-Front-Close2.jpg | ||
Tektronix-570-Inside-Right-Close3.jpg | Tektronix-570-Inside-Right-Close3.jpg | ||
</gallery> | |||
=== Tektronix 570 Serial Number 5055 === | |||
<gallery> | |||
tek_570_sn5055_1.jpg | tek_570_sn5055_1.jpg | ||
tek_570_sn5055_2.jpg | tek_570_sn5055_2.jpg | ||
Line 64: | Line 71: | ||
tek_570_sn5055_11.jpg | tek_570_sn5055_11.jpg | ||
tek_570_sn5055_12.jpg | tek_570_sn5055_12.jpg | ||
</gallery> | |||
=== Tektronix 570 Serial Number 5148 === | |||
<gallery> | |||
tek_570_sn5148_1.jpg | tek_570_sn5148_1.jpg | ||
tek_570_sn5148_2.jpg | tek_570_sn5148_2.jpg | ||
Line 76: | Line 86: | ||
tek_570_sn5148_11.jpg | tek_570_sn5148_11.jpg | ||
tek_570_sn5148_12.jpg | tek_570_sn5148_12.jpg | ||
</gallery> | |||
=== Tektronix 570 Serial Number 5429 === | |||
<gallery> | |||
Tek 570 sn5429 1.jpg | Tek 570 sn5429 1.jpg | ||
Tek 570 sn5429 2.jpg | Tek 570 sn5429 2.jpg | ||
Line 85: | Line 98: | ||
</gallery> | </gallery> | ||
===Adaptors=== | ===Adaptors for Different Tube Bases=== | ||
<gallery> | <gallery> | ||
Tek 570 12-pin fixture 1.jpg|12-pin adaptor | Tek 570 12-pin fixture 1.jpg|12-pin adaptor |
Revision as of 08:29, 17 February 2020
The Tektronix 570 is a curve tracer for tubes, introduced in 1955. It sweeps the plate voltage between zero and a selectable maximum voltage while "stepping" the control grid through a set of voltages.
A selectable screen voltage is available for testing tubes with screens. The plate voltage is measured and applied to the X-axis of the display. Plate current is measured and amplified and is applied to the Y-axis of the display.
Key Specifications
- please add
Internals
The 570 contains five transformers:
- T310: center-tapped isolation transformer for plate sweep
- T340: multitap transformer for heater voltages
- T401: multitap autotransformer for selecting peak plate voltage, feeds T310
- T501: transformer for floating supplies and screen voltage supply
- T620: transformer for 60 kHz HV power oscillator for CRT voltages
The screen supply is regulated and uses a 6CD6GA tube as the series regulator.
The vertical and horizontal amplifiers are almost identical. The first stage is a differential amplifier made of two 6AU6 tubes. The second stage is a differential amplifier made of both halves of a 6BQ7A.
Pictures
Early Tektronix 570
Tektronix 570 Serial Number 5010
Tektronix 570 Serial Number 5055
Tektronix 570 Serial Number 5148
Tektronix 570 Serial Number 5429
Adaptors for Different Tube Bases
-
12-pin adaptor
-
12-pin adaptor
-
7-pin miniature adaptor
-
7-pin miniature adaptor