067-0589-00: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
The '''Tektronix 067-0589-00 Rigid Plug-In Extension''' is used for operating [[7000-series plug-ins]] outside the mainframe for repair, maintenance and calibration. | The '''Tektronix 067-0589-00 Rigid Plug-In Extension''' is used for operating [[7000-series plug-ins]] outside the mainframe for repair, maintenance and calibration. | ||
It is based on a printed circuit board and has a guide rail holding a single-width plug-in. The high-speed signals (vertical, trigger) are carried by coax cables that have BNC couplers in the middle, allowing the signal path to be interrupted for measurement or to feed an external signal into the mainframe. | It is based on a printed circuit board and has a guide rail holding a single-width plug-in. | ||
The high-speed signals (vertical, trigger) are carried by coax cables that have BNC couplers in the middle, allowing the signal path to be interrupted for measurement, or to feed an external signal into the mainframe. | |||
==Manuals== | ==Manuals== | ||
Line 8: | Line 10: | ||
==Pictures== | ==Pictures== | ||
<gallery> | <gallery> | ||
extender_2.jpg | full view of 067-0589-00 | |||
extender_5.jpg | extender inserted into mainframe | |||
extender_4.jpg | 7A26 plugged into extender for servicing | |||
extender_1.jpg | |||
Tek 067-0589-00 1.jpg | Tek 067-0589-00 1.jpg | ||
Tek 067-0589-00 2.jpg | Tek 067-0589-00 2.jpg | ||
Line 13: | Line 19: | ||
Tek 067-0589-00 4.jpg | Tek 067-0589-00 4.jpg | ||
Tek 067-0589-00 5.jpg | Tek 067-0589-00 5.jpg | ||
extender_3.jpg | Broken original connector | |||
Tek 067-0589-00 connector replacement 1.jpg | Broken connector replaced by modern alternative | |||
extender_3.jpg | Tek 067-0589-00 connector replacement 2.jpg | Broken connector replaced by modern alternative | ||
</gallery> | </gallery> | ||
Revision as of 10:56, 31 October 2020
The Tektronix 067-0589-00 Rigid Plug-In Extension is used for operating 7000-series plug-ins outside the mainframe for repair, maintenance and calibration.
It is based on a printed circuit board and has a guide rail holding a single-width plug-in.
The high-speed signals (vertical, trigger) are carried by coax cables that have BNC couplers in the middle, allowing the signal path to be interrupted for measurement, or to feed an external signal into the mainframe.
Manuals
Pictures
-
full view of 067-0589-00
-
extender inserted into mainframe
-
7A26 plugged into extender for servicing
-
-
-
-
-
-
-
Broken original connector
-
Broken connector replaced by modern alternative
-
Broken connector replaced by modern alternative