130: Difference between revisions

From TekWiki
Jump to navigation Jump to search
Line 64: Line 64:
</gallery>
</gallery>


=== Early 130 Style ===
=== 130 Style at serial# 842: still narrow and boxy, but with blue case ===
<gallery>
<gallery>
Tek 130 sn842 1.jpg
Tek 130 sn842 1.jpg

Revision as of 23:58, 2 February 2021

LC 130, SN 101-5000 and 5001-Up

The Tektronix Type 130 is a self-contained instrument, designed by Cliff Moulton and introduced in 1959, that measures inductance and capacitance.

There are at least two versions of Type 130. Early units (SN 101-5000) have a narrow boxy case that slides off the chassis, brown paint, backlit meter, and are marked "TYPE 130 L,C METER". Later units (SN 5001-Up) have a wider, rounded case with side panels that pop off, blue paint, non-backlit meter, and are marked "TYPE 130 L-C METER".

Key Specifications

Ranges 3, 10, 30, 100 or 300 pF / 3, 10, 30, 100 or 300 μH full scale
Accuracy 3% FS, 1% FS with "careful" calibration using S-30 Delta Standard
Measurement voltage <1 V for capacitors, <0.25 V for inductors, 120-140 kHz
Guard output 250 Ω source impedance, can drive 200 pF
DUT connection UHF connector (DUT) + 4 mm jack (guard)

Manuals

Links

Internals

The 130 contains an LC oscillator with a tank circuit formed by the device under test and a capacitor or inductor internal to the 130. The oscillator's frequency is measured by mixing it down using a fixed reference frequency, generating a pulse at each zero-crossing, and integrating (low-pass filtering) the pulse train. This produces a voltage that is proportional to the frequency difference between the LC oscillator and the reference oscillator. This voltage is displayed on a d'Arsonval (moving coil) meter on the front panel of the 130.

Pictures

130 External

130 Internal

130 Style at serial# 842: still narrow and boxy, but with blue case