manufacturer=Nelson-Ross |type=PSA-011| | |||
summary=20 kHz Spectrum Analzyer| | summary=20 kHz Spectrum Analzyer| | ||
image=Nelson-ross-psa011-2.jpg | | image=Nelson-ross-psa011-2.jpg | | ||
Line 6: | Line 6: | ||
introduced=(?) | | introduced=(?) | | ||
discontinued=(?) | | discontinued=(?) | | ||
series= | series=500-series scopes| | ||
manuals= | manuals= | ||
* [[Media:Nelson-ross psa-001 002 003 011 012 013 plug-ins instruction sch.pdf|Manual for Nelson-Ross 001, 002, 003, 011, 012, and 013 (PDF)]] | * [[Media:Nelson-ross psa-001 002 003 011 012 013 plug-ins instruction sch.pdf|Manual for Nelson-Ross 001, 002, 003, 011, 012, and 013 (PDF)]] |
Revision as of 04:43, 9 August 2021
The Nelson-Ross PSA-011 is a spectrum analyzer plug-in for 500-series scopes. The center frequency range is 10 Hz to 20 kHz. It can display amplitude in linear or log scale.
The input is high-impedance and is AC-coupled. The PSA-011 is a single-conversion architecture with a pair of 6BH6 tubes serving as a balanced mixer. After IF filtering and amplification, the signal is detected using a 1N34A germanium diode. The detected voltage from the diode directly drives pin 3 (vertical -) of the scope plug-in interface connector. Pin 1 (vertical +) of the scope plug-in interface connector is fed a DC vertical position voltage by the PSA-011.
The voltage-controlled local oscillator is tuned using a variable-reactance tube, V6, a 6201.
There were at least two major versions produced, without changing the model number. Compare the picture from the manual below with the other front panel photographs.
There was also a tracking generator, called the Nelson Ross 101 SYNCHRO-SWEEP Generator. These are very rare.
Specifications
please add
Pictures
-
Front panel, as shown in manual.
-
Front
-
Front 2
-
Front right
-
Front left
-
Bottom
-
Bottom 2
-
Left
-
Rear right
-
Rear
-
Rear 2
-
Rear 3
-
Schematic