Nelson-Ross PSA-011: Difference between revisions
m (→top: clean up, replaced: {{Plugin Sidebar 2 → {{Plugin Sidebar, title=Nelson-Ross → manufacturer=Nelson-Ross |type= , series=500-series scopes → series=500-series scopes) |
No edit summary |
||
Line 1: | Line 1: | ||
{{Plugin Sidebar| | {{Plugin Sidebar| | ||
manufacturer=Nelson-Ross |type=PSA-011| | manufacturer=Nelson-Ross |type=PSA-011| | ||
summary=20 kHz Spectrum Analzyer| | summary=20 kHz Spectrum Analzyer plug-in| | ||
image=Nelson-ross-psa011-2.jpg | | image=Nelson-ross-psa011-2.jpg | | ||
caption=Nelson-Ross PSA-011 front view| | caption=Nelson-Ross PSA-011 front view| |
Revision as of 04:47, 9 August 2021
The Nelson-Ross PSA-011 is a spectrum analyzer plug-in for 500-series scopes. The center frequency range is 10 Hz to 20 kHz. It can display amplitude in linear or log scale.
The input is high-impedance and is AC-coupled. The PSA-011 is a single-conversion architecture with a pair of 6BH6 tubes serving as a balanced mixer. After IF filtering and amplification, the signal is detected using a 1N34A germanium diode. The detected voltage from the diode directly drives pin 3 (vertical -) of the scope plug-in interface connector. Pin 1 (vertical +) of the scope plug-in interface connector is fed a DC vertical position voltage by the PSA-011.
The voltage-controlled local oscillator is tuned using a variable-reactance tube, V6, a 6201.
There were at least two major versions produced, without changing the model number. Compare the picture from the manual below with the other front panel photographs.
There was also a tracking generator, called the Nelson Ross 101 SYNCHRO-SWEEP Generator. These are very rare.
Specifications
please add
Pictures
-
Front panel, as shown in manual.
-
Front
-
Front 2
-
Front right
-
Front left
-
Bottom
-
Bottom 2
-
Left
-
Rear right
-
Rear
-
Rear 2
-
Rear 3
-
Schematic