T5191: Difference between revisions

From TekWiki
Jump to navigation Jump to search
m (clean up)
Line 1: Line 1:
The ''' Tektronix T519''' aka '''T5190''' (part number  154 -356 / 154-0356-00 )) is the CRT for early  [[519|1 GHz Model 519 scope]] (serial numbers  1016 and below) .
{{CRT
|Manufacturer=Tektronix
|Model=T519 aka T5190, T5191, T5192
|Part_nos=154-0356-00, 154-0308-00
|Description=1 GHz CRT
|Used_in=519;
|Designers=
}} for the [[519]] scope.


The '''Tektronix T5191''' (part number 154-308 / 154-0308-00) is the CRT used in the 1 GHz Model 519 scope (serial numbers 1017 and up).
The usable screen area was 6 × 2 divisions. Total accelerating voltage in the 519 was 24 kV.


The usable screen area was 6 × 2 divisions. Total accelerating voltage in the 519 was 24 kV.  The tube has 125 Ω [[GR-874 connector]]s for signal and termination connections to the [[distributed deflection plates | distributed vertical deflection plates]] that consist of S-shaped striplines. These were individually tuned for optimum response on a [[time-domain reflectometer]] before the deflection system was inserted into the tube during manufacturing.
The tube has 125 Ω [[GR-874 connector]]s for signal and termination connections to the [[distributed deflection plates | distributed vertical deflection plates]] that consist of S-shaped striplines.  
These were individually tuned for optimum response on a [[time-domain reflectometer]] before the deflection system was inserted into the tube during manufacturing.


Each tube was individually characterized for rise time and deflection sensitivity.
Each tube was individually characterized for rise time and deflection sensitivity. The precise values (on the order of 350 ps and 10 V/Div, respectively) were written on the CRT and on the CRT bezel.
The precise values (on the order of 350 ps and 10 V/Div, respectively) were written on the CRT and on the CRT bezel.
The spot side of the T5191 CRT is unusually small (0.1 mm).


The spot side of the T5191 CRT is unusually small: 0.1 mm.
The [[T5192]] is a special variant with bandwidth of 3 GHz.
The [[T5192]] is a special variant with bandwidth of 3 GHz


The 1966 catalog lists the price of a 154-0308-00 replacement CRT as $1,000 (2018 value $7,780).
The 1966 catalog lists the price of a 154-0308-00 replacement CRT as $1,000 (~$8,400 in 2021 dollars).
 
==Part numbers==
* T519 / T5190: 154-356 / 154-0356-00 ([[519]] serial numbers 1016 and below)
* T5191: 154-308 / 154-0308-00 ([[519]] serial numbers 1017 and up)


==Datasheet==
==Datasheet==
Line 18: Line 29:
* [[Media:T519P_REV_B.pdf|Tektronix T519 CRT Data, Rev B (PDF, OCR)]]
* [[Media:T519P_REV_B.pdf|Tektronix T519 CRT Data, Rev B (PDF, OCR)]]
* [[Media:Tek T5191 CRT Data Rev C.pdf|Tektronix T5191 CRT Data, Rev C (PDF, needs OCR)]]
* [[Media:Tek T5191 CRT Data Rev C.pdf|Tektronix T5191 CRT Data, Rev C (PDF, needs OCR)]]


==Pictures==
==Pictures==

Revision as of 01:09, 11 August 2021

The Tektronix T519 aka T5190, T5191, T5192  (P/N 154-0356-00, 154-0308-00) is a 1 GHz CRT for the 519 scope.

The usable screen area was 6 × 2 divisions. Total accelerating voltage in the 519 was 24 kV.

The tube has 125 Ω GR-874 connectors for signal and termination connections to the distributed vertical deflection plates that consist of S-shaped striplines. These were individually tuned for optimum response on a time-domain reflectometer before the deflection system was inserted into the tube during manufacturing.

Each tube was individually characterized for rise time and deflection sensitivity. The precise values (on the order of 350 ps and 10 V/Div, respectively) were written on the CRT and on the CRT bezel. The spot side of the T5191 CRT is unusually small (0.1 mm).

The T5192 is a special variant with bandwidth of 3 GHz.

The 1966 catalog lists the price of a 154-0308-00 replacement CRT as $1,000 (~$8,400 in 2021 dollars).

Part numbers

  • T519 / T5190: 154-356 / 154-0356-00 (519 serial numbers 1016 and below)
  • T5191: 154-308 / 154-0308-00 (519 serial numbers 1017 and up)

Datasheet

Pictures