3A10: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
m (→‎top: clean up, replaced: title=Tektronix → manufacturer=Tektronix |series=560-series scopes |type=, {{Plugin Sidebar 2 → {{Plugin Sidebar, series=560-series scopes → designers=)
Line 1: Line 1:
{{Plugin Sidebar 2 |
{{Plugin Sidebar |
title=Tektronix 3A10 |
manufacturer=Tektronix |series=560-series scopes |type= 3A10 |
summary=Transducer Amplifier |
summary=Transducer Amplifier |
image=Tek 3a10 front.jpg |
image=Tek 3a10 front.jpg |
caption=Tektronix 3A10 front |
caption=Tektronix 3A10 front |
series=[[560-series scopes]]|
designers= |
introduced=1971 |
introduced=1971 |
discontinued=1975 |
discontinued=1975 |
Line 12: Line 12:
The '''Tektronix 3A10''' is a differential amplifier plug-in for [[560-series scopes]].
The '''Tektronix 3A10''' is a differential amplifier plug-in for [[560-series scopes]].


It is intended for use with transducers and for that purpose it has a DC-coupled differential input
It is intended for use with transducers and for that purpose it has a DC-coupled differential input and a variable voltage supply for powering the transducer.  It also has a 6-pin input connector ([[Bendix connector|Bendix MS3101A-10-6S]]) to directly connect to the [[015-0169-00|015-0169-00 Strain Gage Adapter]].
and a variable voltage supply for powering the transducer.  It also has a 6-pin input connector  
([[Bendix connector|Bendix MS3101A-10-6S]]) to directly connect to the [[015-0169-00|015-0169-00 Strain Gage Adapter]].


The 3A10 circuit is partially based on the [[1A7A]]'s.
The 3A10 circuit is partially based on the [[1A7A]]'s.

Revision as of 11:25, 14 August 2021

Tektronix 3A10
Transducer Amplifier
Tektronix 3A10 front

Compatible with 560-series scopes

Produced from 1971 to 1975

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 3A10 is a differential amplifier plug-in for 560-series scopes.

It is intended for use with transducers and for that purpose it has a DC-coupled differential input and a variable voltage supply for powering the transducer. It also has a 6-pin input connector (Bendix MS3101A-10-6S) to directly connect to the 015-0169-00 Strain Gage Adapter.

The 3A10 circuit is partially based on the 1A7A's.

Key Specifications

Deflection 10 μV/Div to 10 V/Div in 1–2–5 sequence
Input impedance 1 MΩ // 47 pF (Volts mode) or 10 MΩ (transducer mode)
Bandwidth 1 MHz, LF limit switchable DC, 0.1 Hz to 10 kHz in six steps, HF limit switchable 100 Hz to 1 MHz in ×3/×10 steps, AC coupling 1.6 Hz
Signal ranges
Range Differential signal DC Offset Common mode
10 μV/Div to 10 mV/Div ±1 V ±1 V ±10 V
20 mV/Div to 0.1 V/Div ±10 V ±10 V ±100 V
0.2 V/Div to 1 V/Div ±100 V ±100 V ±500 V
2 V/Div to 10 V/Div ±1000 V ±1000 V ±500 V


Pictures