SC501: Difference between revisions
Jump to navigation
Jump to search
m (→top: clean up, replaced: manuals= → designers= |manuals=) |
No edit summary |
||
Line 4: | Line 4: | ||
* [[Media:TB-9-6625-2173-35.pdf|US Army Calbration Guide for SC501, SC502, and SC504 (PDF)]] | * [[Media:TB-9-6625-2173-35.pdf|US Army Calbration Guide for SC501, SC502, and SC504 (PDF)]] | ||
}} | }} | ||
The SC501 uses the [[155-0055-00]] (U200) for trigger and sweep. | The SC501 uses the [[155-0055-00]] (U200) for trigger and sweep. | ||
Line 40: | Line 39: | ||
Tek sc501 z axis and crt schematic.jpg|Z-Axis and CRT schematic | Tek sc501 z axis and crt schematic.jpg|Z-Axis and CRT schematic | ||
</gallery> | </gallery> | ||
{{Custom ICs|Telequipment SC501}} |
Revision as of 05:04, 16 August 2021
The Tektronix SC501 is a 5 MHz oscilloscope plug-in for the TM500 system.
The SC501 uses the 155-0055-00 (U200) for trigger and sweep.
The MR501 X-Y monitor shares part of the SC501's design.
The CRT cathode is directly heated and at −980 V.
Key Specifications
Bandwidth | 5 MHz |
---|---|
Deflection | 10 mV/Div, 100 mV/Div, 1 V/Div, plus variable control (10 mV/Div to 10 V/Div overall) |
Sweep | 1 μs/Div to 100 ms/Div in decade steps, plus variable control and ×5 magnifier (200 ns/Div to 1 s/Div overall) |
Input impedance | 1 MΩ // 47 pF |
CRT | 6 × 10 divisions of 0.203" (5.16 mm) i.e. 1.2" × 2" (31 mm × 51.5 mm), 154-0699-00 tube |
Features |
|
Pictures
-
-
-
SC 501 with blue CRT filter
-
-
-
-
-
-
-
-
Vertical schematic
-
Horizontal schematic
-
Low Voltage Supplies schematic
-
Z-Axis and CRT schematic
Custom ICs used in the Telequipment SC501
No results