067-1201-99: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 9: Line 9:


It can also be used as a simple generic power supply delivering +5 V, 1 A (from the shared +12 V unregulated supply via a 7805 type regulator) and ±15 V, 400 mA with current limiting (the latter using the mainframe's pass transistors).  For this mode, the rotary switch must be in position 3 and the toggle switch set to DC.
It can also be used as a simple generic power supply delivering +5 V, 1 A (from the shared +12 V unregulated supply via a 7805 type regulator) and ±15 V, 400 mA with current limiting (the latter using the mainframe's pass transistors).  For this mode, the rotary switch must be in position 3 and the toggle switch set to DC.
==Jared Cabot's 067-1201-99 clone==
* [https://www.youtube.com/watch?v=Afwqtc6Fxd4 Build a Tektronix TM500 Mainframe Tester]
* [https://www.youtube.com/watch?v=vXd10kKFFGw Repair and Test a Tektronix TM502A Mainframe] (shows how to use a 067-1201-99)
* [https://groups.io/g/TekScopes/files/Tek%20TM500%20Power%20Module%20Tester%20067-1201-99%20New%20Ver Schematics, photos, Gerber files etc.]


==Pictures ==
==Pictures ==

Revision as of 01:59, 6 September 2021

Tektronix 067-1201-99
Power Module Tester and Utility Power Supply
Tektronix 067-1201-99

Produced from (?) to (?)

Manuals
Manuals – Specifications – Links – Pictures

The Tektronix 067-1201-99 is a Power Module Tester and Utility Power Supply plug-in for the TM500 system.

It allows external measurement of the mainframe's pass transistors, AC and DC supplies for a plug-in slot.

It can also be used as a simple generic power supply delivering +5 V, 1 A (from the shared +12 V unregulated supply via a 7805 type regulator) and ±15 V, 400 mA with current limiting (the latter using the mainframe's pass transistors). For this mode, the rotary switch must be in position 3 and the toggle switch set to DC.

Jared Cabot's 067-1201-99 clone

Pictures