|summary=50 MHz passive | |summary=50 MHz, x10, passive probe | ||
|image=Tek p6149 1.jpg | |image=Tek p6149 1.jpg | ||
|caption=Tektronix P6149 | |caption=Tektronix P6149 | ||
Line 11: | Line 11: | ||
* [https://w140.com/Tektronix_P6149_Datasheet.pdf Tektronix P6149 Datasheet (PDF)] | * [https://w140.com/Tektronix_P6149_Datasheet.pdf Tektronix P6149 Datasheet (PDF)] | ||
}} | }} | ||
The '''Tektronix P6149''' is a passive | The '''Tektronix P6149''' is a 50 MHz, ×10, passive, [[miniature modular probe]] | ||
The impedance at the tip is 10 MΩ in parallel with 15.5 pF. | The impedance at the tip is 10 MΩ in parallel with 15.5 pF. | ||
Revision as of 09:05, 7 November 2021
The Tektronix P6149 is a 50 MHz, ×10, passive, miniature modular probe The impedance at the tip is 10 MΩ in parallel with 15.5 pF.
The probe connects to the oscilloscope with a BNC connector, and the compensation range is 20 pF to 62 pF.
The maximum input voltage is 500 V at DC, decreasing to about 25 V at 50 MHz.