The '''Tektronix P6010''' is a probe designed primarily for use with the [[S-5]] sampling head. | The '''Tektronix P6010''' is a probe designed primarily for use with the [[S-5]] sampling head. | ||
The P6010 is a miniature passive probe designed for use with Tektronix wide-band oscilloscopes. | The P6010 is a miniature passive probe designed for use with Tektronix wide-band oscilloscopes. | ||
{{BeginSpecs}} | {{BeginSpecs}} | ||
{{Spec | ATTENUATION | 10X }} | {{Spec | ATTENUATION | 10X }} | ||
{{Spec | INPUT RESISTANCE | 10 | {{Spec | INPUT RESISTANCE | 10 MΩ }} | ||
{{Spec | INPUT CAPACITANCE | | {{Spec | INPUT CAPACITANCE | <10 to <14.5 pF, depending on cable length }} | ||
{{Spec | PROBE RISETIME | Less than | {{Spec | COMPENSATION RANGE | 14-21 pF, factory compensated to 20 pF }} | ||
{{Spec | TYPICAL RISETIME | | {{Spec | PROBE RISETIME | Less than 2 nsec }} | ||
{{Spec | VOLTAGE RATING | Is 500V DC | {{Spec | TYPICAL RISETIME | 7 nsec with [[453]] scope }} | ||
{{Spec | STANDARD CABLE | Is 3.5 | {{Spec | BANDWIDTH | 150 MHz }} | ||
{{Spec | VOLTAGE RATING | Is 500V DC + AC Peak, derate above 12 MHz }} | |||
{{Spec | STANDARD CABLE | Is 3.5, 6, or 9 feet long, terminated in a [[BNC]] connector }} | |||
{{EndSpecs}} | {{EndSpecs}} | ||
==Pictures== | ==Pictures== |
Revision as of 16:05, 7 December 2021
The Tektronix P6010 is a probe designed primarily for use with the S-5 sampling head. The P6010 is a miniature passive probe designed for use with Tektronix wide-band oscilloscopes.
Key Specifications
ATTENUATION | 10X |
---|---|
INPUT RESISTANCE | 10 MΩ |
INPUT CAPACITANCE | <10 to <14.5 pF, depending on cable length |
COMPENSATION RANGE | 14-21 pF, factory compensated to 20 pF |
PROBE RISETIME | Less than 2 nsec |
TYPICAL RISETIME | 7 nsec with 453 scope |
BANDWIDTH | 150 MHz |
VOLTAGE RATING | Is 500V DC + AC Peak, derate above 12 MHz |
STANDARD CABLE | Is 3.5, 6, or 9 feet long, terminated in a BNC connector |