P6015: Difference between revisions
Jump to navigation
Jump to search
mNo edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
{{Probe Sidebar | |||
The '''Tektronix P6015''' is a | |manufacturer=Tektronix | ||
|model=P6015 | |||
|summary=20(40) kV, ×1000 Passive Probe | |||
|image=Tek_P6015_1.jpg | |||
|caption=P6015 | |||
|for=1 MΩ scope inputs | |||
|introduced=(?) | |||
|discontinued=(?) | |||
|manuals= | |||
* [https://w140.com/p6015.pdf Tektronix P6015 Manual] (Copyright date 1963) | |||
* [https://w140.com/P6015_070-0373-02.pdf Tektronix P6015 Manual] (Revision date 1985) | |||
* [https://w140.com/P6015A_tek_original.pdf Tektronix P6015A Manual] | |||
* [https://w140.com/tek_p6015a_mod.pdf Tektronix P6015A Manual with Schematic] | |||
* [https://w140.com/tek_p6007_p6009_p6015_cat.pdf Tektronix P6007 P6009 P6015 Catalog Description] | |||
}} | |||
The '''Tektronix P6015''' is a 1000× high-voltage probe usable up to 20 kV (40 kV peak pulse). | |||
It can be operated with or without dielectric filling but without this filling, the maximum voltage is reduced to 13 kV (18 kV peak). | |||
The original filling material, [[wikipedia: 1,2-Dichlorotetrafluoroethane|Freon-114 aka Fluorocarbon 114 (R-114, CFC-114)]], is no longer available due to its ozone-depleting properties. In later models (P6015A), a silicone based replacement is used. | |||
The P6015 has a compensating circuit at the scope end of the cable with multiple adjustable RC constants. | The P6015 has a compensating circuit at the scope end of the cable with multiple adjustable RC constants. | ||
{{BeginSpecs}} | {{BeginSpecs}} | ||
{{Spec | Attenuation ratio | | {{Spec | Attenuation ratio | 1000× }} | ||
{{Spec | Input impedance | 100 MΩ // 3 pF }} | {{Spec | Input impedance | 100 MΩ // 3 pF }} | ||
{{Spec | Rise time | 4. | {{Spec | Rise time | 4.67 ns (10' cable), 14 ns (25' cable) }} | ||
{{Spec | Bandwidth | 75 MHz (10' cable), 25 MHz (25' cable) }} | {{Spec | Bandwidth | 75 MHz (10' cable), 25 MHz (25' cable) }} | ||
{{Spec | Compensation Range | 15-50 pF }} | {{Spec | Compensation Range | 15-50 pF }} | ||
{{Spec | Max. input voltage | | {{Spec | Max. input voltage | | ||
Line 17: | Line 33: | ||
}} | }} | ||
{{EndSpecs}} | {{EndSpecs}} | ||
==Links== | ==Links== | ||
Line 34: | Line 41: | ||
==Pictures== | ==Pictures== | ||
<gallery> | <gallery> | ||
P6015 | Tek P6015 box.jpg | Tektronix P6015 in box | ||
Tek_P6015_1.jpg | Tek_P6015_1.jpg | ||
Tek_P6015_2.jpg | Tek_P6015_2.jpg | ||
Tek_P6015_3.jpg | Tek_P6015_3.jpg | ||
Tek_P6015_4.jpg | Tek_P6015_4.jpg | ||
P6015 BW.png | |||
Tek p6015 schem.png | |||
Tek P6015 derating.jpg | Derating curves | |||
Tek hv dielectric fluid.jpg | Can of Freon Dielectric Fluid | |||
Tek P6015 term box.jpg | Termination box | |||
</gallery> | </gallery> | ||
[[Category:1 MΩ Oscilloscope probes]] | [[Category:1 MΩ Oscilloscope probes]] | ||
[[Category:High voltage oscilloscope probes]] | [[Category:High voltage oscilloscope probes]] |
Revision as of 05:05, 9 December 2021
The Tektronix P6015 is a 1000× high-voltage probe usable up to 20 kV (40 kV peak pulse).
It can be operated with or without dielectric filling but without this filling, the maximum voltage is reduced to 13 kV (18 kV peak). The original filling material, Freon-114 aka Fluorocarbon 114 (R-114, CFC-114), is no longer available due to its ozone-depleting properties. In later models (P6015A), a silicone based replacement is used.
The P6015 has a compensating circuit at the scope end of the cable with multiple adjustable RC constants.
Key Specifications
Attenuation ratio | 1000× |
---|---|
Input impedance | 100 MΩ // 3 pF |
Rise time | 4.67 ns (10' cable), 14 ns (25' cable) |
Bandwidth | 75 MHz (10' cable), 25 MHz (25' cable) |
Compensation Range | 15-50 pF |
Max. input voltage |
|
Links
Pictures
-
Tektronix P6015 in box
-
-
-
-
-
-
-
Derating curves
-
Can of Freon Dielectric Fluid
-
Termination box