P6015: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
(Added P6015A product brochure, organised manual descriptions)
Line 9: Line 9:
|discontinued=(?)
|discontinued=(?)
|manuals=
|manuals=
* [https://w140.com/p6015.pdf Tektronix P6015 Manual] (Copyright date 1963)
* [https://w140.com/p6015.pdf P6015 Instruction Manual 070-0373-01] (Copyright date 1963)
* [https://w140.com/P6015_070-0373-02.pdf Tektronix P6015 Manual] (Revision date 1985)
* [https://w140.com/P6015_070-0373-02.pdf P6015 Instruction Manual 070-0373-02] (Revision date 1985)
* [https://w140.com/P6015A_tek_original.pdf Tektronix P6015A Manual]
* [https://w140.com/tek_p6015a_mod.pdf P6015A Manual with Schematic 070-8223-04]
* [https://w140.com/tek_p6015a_mod.pdf Tektronix P6015A Manual with Schematic]
* [https://w140.com/P6015A_tek_original.pdf P6015A Instruction Manual 070-8223-05]
* [https://w140.com/tek_p6007_p6009_p6015_cat.pdf Tektronix P6007 P6009 P6015 Catalog Description]
* [https://w140.com/tek_p6007_p6009_p6015_cat.pdf P6007 P6009 P6015 Catalog Description]
* [[media:51W-8217-2.pdf|P6015A Product Brochure]]
}}
}}
The '''Tektronix P6015''' is a 1000× high-voltage probe usable up to 20 kV (40 kV peak pulse).   
The '''Tektronix P6015''' is a 1000× high-voltage probe usable up to 20 kV (40 kV peak pulse).   



Revision as of 10:01, 27 February 2022

Tektronix P6015
20(40) kV, ×1000 Passive Probe
P6015

Compatible with 1 MΩ scope inputs

Produced from (?) to (?)

Manuals


Manuals – Specifications – Links – Pictures

The Tektronix P6015 is a 1000× high-voltage probe usable up to 20 kV (40 kV peak pulse).

It can be operated with or without dielectric filling but without this filling, the maximum voltage is reduced to 13 kV (18 kV peak). The original filling material, Freon-114 aka Fluorocarbon 114 (R-114, CFC-114), is no longer available due to its ozone-depleting properties. In later models (P6015A), a silicone based replacement is used.

The P6015 has a compensating circuit at the scope end of the cable with multiple adjustable RC constants.

Key Specifications

Bandwidth 75 MHz (10' cable), 25 MHz (25' cable)
Risetime 4.67 ns (10' cable), 14 ns (25' cable)
Attenuation 1000×
Input impedance 100 MΩ // 3 pF
Compensation range 15-50 pF
Max. input voltage
  • With dielectric filling: 20 kV DC or RMS to 100 kHz, pulse up to 40 kV (10%, < 0.1s)
  • Without dielectric filling: 13 kV DC or RMS to 500 kHz, pulse up to 18 kV (10%, < 0.1s)

Links