P6150: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 1: | Line 1: | ||
{{Probe Sidebar | |||
|manufacturer=Tektronix | |||
|model=P6150 | |||
|summary=9 GHz passive probe | |||
|image=tek_p6150_1.jpg | |||
|caption=P6150 probe | |||
|for=50 Ω scope inputs | |||
|introduced=1989 | |||
|discontinued=(?) | |||
|manuals= | |||
* [[Media:070-7173-01.pdf|Tektronix P6150 Manual]] | |||
}} | |||
The '''Tektronix P6150''' is a 9 GHz probe for oscilloscopes with 50 Ω inputs. | The '''Tektronix P6150''' is a 9 GHz probe for oscilloscopes with 50 Ω inputs. | ||
It was designed for use with the [[SD-24]] and [[SD-26]] sampling heads, but can be used with any 50 Ω instrumentation. | It was designed for use with the [[SD-24]] and [[SD-26]] sampling heads, but can be used with any 50 Ω instrumentation. | ||
Line 4: | Line 16: | ||
The P6150 comes standard with 1x and 10x attenuators. | The P6150 comes standard with 1x and 10x attenuators. | ||
{{MissingSpecs}} | |||
The P6150 feeding the standard 1 meter cable (part number [[174-1341-00]]) feeding an [[SD-24]] produces a system rise time of 43 picoseconds. | The P6150 feeding the standard 1 meter cable (part number [[174-1341-00]]) feeding an [[SD-24]] produces a system rise time of 43 picoseconds. | ||
Line 10: | Line 23: | ||
In 10x configuration, the P6150 has an input capacitance of no more than 0.15 pF, input resistance of 500 Ω, and maximum input voltage of 12.5 V<sub>RMS</sub>. | In 10x configuration, the P6150 has an input capacitance of no more than 0.15 pF, input resistance of 500 Ω, and maximum input voltage of 12.5 V<sub>RMS</sub>. | ||
== | ==Pictures== | ||
<gallery> | <gallery> | ||
tek_p6150_1.jpg | tek_p6150_1.jpg |
Latest revision as of 01:46, 21 July 2022
The Tektronix P6150 is a 9 GHz probe for oscilloscopes with 50 Ω inputs. It was designed for use with the SD-24 and SD-26 sampling heads, but can be used with any 50 Ω instrumentation.
The P6150 comes standard with 1x and 10x attenuators.
Key Specifications
- please add
The P6150 feeding the standard 1 meter cable (part number 174-1341-00) feeding an SD-24 produces a system rise time of 43 picoseconds.
When the optional 22 cm cable (part number 174-1120-00) is used instead of the 1 meter cable, rise time drops to 30 picoseconds.
In 10x configuration, the P6150 has an input capacitance of no more than 0.15 pF, input resistance of 500 Ω, and maximum input voltage of 12.5 VRMS.