J16: Difference between revisions

From TekWiki
Jump to navigation Jump to search
(changed to generic template, it's not a scope)
(Added accessories)
Line 36: Line 36:
* Option 1 - 230 VAC 50 operation (battery charger)
* Option 1 - 230 VAC 50 operation (battery charger)
* Option 2 - Metric Readout
* Option 2 - Metric Readout
* Option 3 - 115 VAC Power Supply
* Option 3 - 115 VAC Internal Power Supply
* Option 4 - 230 VAC Power Supply
* Option 4 - 230 VAC Internal Power Supply
* Option 07 - BCD/Analog output (25 pin connector on top of J16)
* Option 07 - BCD/Analog output (25 pin connector on top of J16)


==Accessories==
==Standard Accessories==
* J6502 - Irradiance Probe
* 016-0305-00 - Light Occluder
* 012-0414-00 - 42-Inch Probe Extender Cable - Connects between the J16 and probe.
* 012-0414-00 - 42-Inch Probe Extender Cable - Connects between the J16 and probe.
* 119-0375-02 - Battery Charger
* 4188-BA - 53-inch long Carrying Strap
* 070-1879-00 - Instruction Manual
== Optional Accessories==
* 016-0527-00 - Filter Holder - Mounts one-inch diameter filters, of up to 3/8-inch thickness, to probes.
* 016-0527-00 - Filter Holder - Mounts one-inch diameter filters, of up to 3/8-inch thickness, to probes.
* 016-0539-00 - Spare Battery Pack
* 016-0539-00 - Spare Battery Pack

Revision as of 09:22, 30 August 2022

Tektronix J16
Digital Photometer/Radiometer
Tektronix J16 Digital Photometer/Radiometer

Produced from (1972) to (?)

Manuals
Manuals – Specifications – Links – Pictures

The Tektronix J16 is a digital photometer. The instrument could be configured to either use rechargeable batteries or line voltage (119-0404-00).

Key Specifications

Measurement Range
  • J6501 or J6511 Illuminance Probes: 0.001 to 1,999 foot candles
  • J6502 or J6512 Irradiance Probes: 0.001 to 1,999 μW/cm²
  • J6503 or J6513 Luminance Probes: 0.1 to 199,900 lamberts
Resolution
  • Illuminance Probes: 0.0001 foot candle
  • Irradiance Probes: 0.0001 μW/cm²
  • Luminance Probes: 0.01 lamberts
System Accuracy Maximum absolute uncertainty ±5%, ±1 digit, on any range; uncertainty of linearity is ±2% or less
Temperature −15 to +40°C (+5 to +104°F) operating, −55 to +75°C (−67 to +167°F) storage
Weight 3.25 pounds (1.5 Kg)
Dimensions Height: 2.375 inches (6 cm), Width: 4.625 inches (12.3 cm), Depth: 8 inches (20.3 cm)

Options

  • Option 1 - 230 VAC 50 operation (battery charger)
  • Option 2 - Metric Readout
  • Option 3 - 115 VAC Internal Power Supply
  • Option 4 - 230 VAC Internal Power Supply
  • Option 07 - BCD/Analog output (25 pin connector on top of J16)

Standard Accessories

  • J6502 - Irradiance Probe
  • 016-0305-00 - Light Occluder
  • 012-0414-00 - 42-Inch Probe Extender Cable - Connects between the J16 and probe.
  • 119-0375-02 - Battery Charger
  • 4188-BA - 53-inch long Carrying Strap
  • 070-1879-00 - Instruction Manual

Optional Accessories

  • 016-0527-00 - Filter Holder - Mounts one-inch diameter filters, of up to 3/8-inch thickness, to probes.
  • 016-0539-00 - Spare Battery Pack
  • 119-0404-00 - AC Power Supply - Allows J16 to be used without batteries.

Illuminance Probes:

Irradiance Probes:

Luminance Probes:

Uncorrected Probes:

LED Probe:


Links

Pictures