P6019: Difference between revisions

From TekWiki
Jump to navigation Jump to search
No edit summary
m (rewording and expanding)
Line 12: Line 12:
* [[Media:Tek p6020 fcp july 1967.pdf]]
* [[Media:Tek p6020 fcp july 1967.pdf]]
}}
}}
The P6019 and [[P6020]] split-core AC current probes were introduced in 1966 together with passive terminations and the [[134|Type 134]] amplifier.
The P6019 is a 125 turn split-core AC current probe introduced in 1966 together with passive termination and the [[134|Type 134]] amplifier.


The probes had no internal frequency compensation components, contrary to their 1969 successor types [[P6021]] and [[P6022]].
The [[P6020]], introduced at the same time, is a 50 turn, higher frequency companion introduced at the same time. 
 
The P6019 and [[P6020]] have no internal frequency compensation components, contrary to their 1969 successors [[P6021]] and [[P6022]].


==Specifications==
==Specifications==

Revision as of 22:01, 30 March 2023

Tektronix P6019
Oscilloscope current probe
Tektronix P6019

Compatible with 134

Produced from 1966 to (?)

Manuals


Manuals – Specifications – Links – Pictures

The P6019 is a 125 turn split-core AC current probe introduced in 1966 together with passive termination and the Type 134 amplifier.

The P6020, introduced at the same time, is a 50 turn, higher frequency companion introduced at the same time.

The P6019 and P6020 have no internal frequency compensation components, contrary to their 1969 successors P6021 and P6022.

Specifications

P6019 + 011-0078-00 passive termination P6019 + 134 P6020 + 011-0079-00 passive termination P6020 + 134
Sensitivity 2 mA/mV or 10 mA/mV 1 mA/Div to 1 A/Div (scope @ 50 mV/Div) 1 mA/mV or 10 mA/mV 1 mA/Div to 1 A/Div (scope @ 50 mV/Div)
Bandwidth (-3 dB) 60 MHz @ 10 mA/mV > 40 MHz 200 MHz @ 10 mA/mV > 70 MHz
LF limit (-3 dB) 450 Hz @ 2 mA/mV, 120 Hz @ 10 mA/mV < 12 Hz 6500 Hz @ 1 mA/mV, 775 Hz @ 10 mA/mV < 50 Hz
Maximum current 15 Ap-p 6 Ap-p

Links

Pictures