Revision as of 02:10, 2 September 2023
The Tektronix P6108 is a passive 100 MHz, ×10, miniature modular probe for 1 MΩ scope inputs. It appears to be the same as the P6105, but without the readout encoding pin. It has a BNC connector.
Key Specifications
Attenuation | 10 × ±3% with 1 MΩ ±2% scope input |
---|---|
Maximum Voltage | 500 V DC + peak AC, derated with frequency |
Compensation range | 15 pF to 47 pF |
Bandwidth | 100 MHz (95 MHz for 3 meter cable) |
Input capacitance | 10.5 pF (1 m), 13 pF (2 m), 15.5 pF (3 m) |