CT-6: Difference between revisions
Jump to navigation
Jump to search
No edit summary |
No edit summary |
||
Line 9: | Line 9: | ||
|discontinued=(?) | |discontinued=(?) | ||
|manuals= | |manuals= | ||
* [[Media:071-0453-00.pdf|Tektronix CT-6 Manual]] | * [[Media:071-0453-00.pdf|Tektronix CT-6 Manual 071-0453-00 Rev.A]] | ||
}} | }} | ||
'''Tektronix CT-6''' | The '''Tektronix CT-6''' is a miniature AC current probe suited for probing low-voltage, high-frequency circuits. | ||
It has a fixed attached cable with an [[SMA connector]]. | |||
{{BeginSpecs}} | |||
{{Spec | Bandwidth | 250 kHz to 1.5 GHz (2 GHz typ.) }} | |||
{{Spec | Rise time | <233 ps (<170 ps typ.) }} | |||
{{Spec | Sensitivity | 5 mV/mA ±3% into 50 Ω load at 50 MHz }} | |||
{{Spec | Max. Current | 120 mA<sub>RMS</sub> cont., 6 A peak }} | |||
{{Spec | Insertion impedance | 1.1 Ω @ 10 MHz, 1.3 Ω @ 100 MHz }} | |||
{{EndSpecs}} | |||
==Links== | |||
{{Documents|Link=CT-6}} | |||
==Pictures== | ==Pictures== |
Latest revision as of 00:56, 20 November 2023
The Tektronix CT-6 is a miniature AC current probe suited for probing low-voltage, high-frequency circuits.
It has a fixed attached cable with an SMA connector.
Key Specifications
Bandwidth | 250 kHz to 1.5 GHz (2 GHz typ.) |
---|---|
Rise time | <233 ps (<170 ps typ.) |
Sensitivity | 5 mV/mA ±3% into 50 Ω load at 50 MHz |
Max. Current | 120 mARMS cont., 6 A peak |
Insertion impedance | 1.1 Ω @ 10 MHz, 1.3 Ω @ 100 MHz |
Links
Documents Referencing CT-6
- (no results)
Pictures
-
-
-
-
-
-
CT-6 Frequency Response