* 34 - Differential probe Add a 1 GHz (probe only) [[P6247]] differential probe. | |||
* 36 - Passive probe Add a 500 MHz [[P6139A]] 10X passive probe. | |||
* 34 - Differential probe Add a 1 GHz (probe only) P6247 differential probe. | * 38 - Active probe Add a 4 GHz (probe only) [[P6249]] 5X, small geometry active probe. | ||
* 36 - Passive probe Add a 500 MHz P6139A 10X passive probe. | * 39 - Differential probe Add a 1.5 GHz (probe only) [[P6248]] small geometry active differential probe. | ||
* 38 - Active probe Add a 4 GHz (probe only) P6249 5X, small geometry active probe. | |||
* 39 - Differential probe Add a 1.5 GHz (probe only) P6248 small geometry active differential probe. | |||
* 1K - Add K420 scope cart | * 1K - Add K420 scope cart | ||
* 1R - Rackmount kit | * 1R - Rackmount kit | ||
* 24 - Add 4 each P6139A passive probes | * 24 - Add 4 each [[P6139A]] passive probes | ||
* 26 - Add 4 each P6245 active probes | * 26 - Add 4 each [[P6245]] active probes | ||
* C3 - Three years calibration Provides three years of calibration | * C3 - Three years calibration Provides three years of calibration | ||
* D1 - Calibration data report Oscilloscope comes with a calibration data report. | * D1 - Calibration data report Oscilloscope comes with a calibration data report. |
Revision as of 11:53, 6 April 2024
The Tektronix TDS694C is a four-channel, 3 GHz, 10 GS/s digital scope. The project codename was 'Screamer'.
No earlier revisions (TDS694B etc) appear to have been released.
These scopes contain ICs in the triggering system that are known to fail, commonly understood to be for thermal reasons. Three ICs are present: Ch 1/2, Ch 3/4, 'Other' (ext trig?). The ICs appear to have poor thermal contact with the PCB; when failed, the scope will no longer trigger on the relevant channels (however, signals will still be acquired). It is possible to transplant these ICs with standard SMT hot-air rework equipment. The 'Other' IC has been used as a donor in some cases.
Do not operate this scope without the case on, WITHOUT extra cooling means.
The low (by modern standards) memory length, coupled with the high sample rate of this scope, means that it is best described as a 'one-shot' (or 'transient') digitizer. At the fastest sweep (100 ps/div), only 3 μs of data can be captured with the standard memory allocation.
Key Specifications
— Acquisition — | |
Sampling rate | 10 GS/s on each channel simultaneously |
Analog bandwidth | 3 GHz (all ranges; 10 mV/div − 1V/div) |
Inputs | 4 Channels; 50 Ω (DC/GND) only |
Resolution | 8 bit |
Record length | 30K samples per channel; 120K samples with option 1M |
Modes | sample, envelope, peak detect, average |
— Misc — | |
Display | 7" diagonal, 640 x 480 color CRT; Zoom |
Trigger modes | Edge, logic, pulse |
Storage | 1.44 Mbyte, 3.5 inch, DOS 3.3-or-later floppy disk. Internal hard disk drive (2.1 Gb capacity) with Option 2M. NVRAM storage for saving waveforms, hardcopies, and setups. Iomega Zip Drive compatible. |
I/O | Full GPIB programmability; VGA output |
Hardcopy output | using GPIB, RS-232, or Centronics ports |
Software
- TDS Family Programming Examples Software 063-1134-00 V1.2 (zip)
- Waveform Converter For Oscilloscopes 066-0002-00 (ZIP)
- AWE Drivers For Tektronix Oscilloscopes 066-0087-00 (ZIP)
- File Transfer Utility From TDS Scope To PC 066-0104-00 (ZIP)
- Telecom Test and I-Pattern Software TTiP 066-0119-00 (ZIP)
- Enhanced Printing Utility for TDS Family 066-0125-00 (ZIP)
- TDS runtime Environment TDSRTE1 066-0127-00 (ZIP)
- WFM to ASCII Waveform Converter - UNIX Version For Sun Spark Stations 066-0176-00 (ZIP)
- Hardcopy from TDS to PC Using HPIP 82335B Interface Card 066-0177-00 (ZIP)
- Example Program To Get Crossing Levels 066-0178-00 (ZIP)
- TDS ISF File To CSV File Conversion Utility 066-0179-00 (ZIP)
- Transfer 2 Byte Data From TDS Oscilloscopes QuickBasic 066-0188-00 (ZIP)
- TDS Waveform Logging Sample Program 066-0194-00 (ZIP)
- Load TDS Floppy MathCAD Files Into MathCAD 066-0196-00 (ZIP)
- Transfer TDS Hardcopy Screens To PC Via GPIB 066-0197-00 (ZIP)
- Transfer Setups Between TDS Oscilloscopes 066-0198-00 (ZIP)
- VB Program To Capture TDS Extended Waveforms 066-0200-00 (ZIP)
- Telecommunications Option for TDS Oscilloscopes 066-0201-00 (ZIP)
- TDS Series WFM File Formatter 066-0489-00 (ZIP)
- Tektronix Wavestar 2012.05.09.11.07.29 16456 EN 066-0934-03 (ZIP, 102MB) Product Key: WSTRO618650124
Options
- 05 - Video Trigger - Oscilloscope comes with tools that allow investigation of a range of NTSC, PAL, SECAM, and high definition TV signals.
- 13 - RS-232C and Centronics hardcopy interfaces - Add RS-232-C and Centronics interface ports.
- 1F - Floppy disk drive - Add 3.5 inch, 1.44 MByte floppy disc drive.
- 1G - 1 GS/s maximum - Limit sample rate from 5 GS/sec to 1 GS/sec when acquiring 1 to 4 channels (Export restriction compliance). (TDS 754D Only)
- 1M - 4M acquisition length - Extends standard acquisition length from 50,000 points per channel to 130,000 samples on three or four channels, 250,000 samples on two channels, and 500,000 samples on one channel.
- 2F - Advanced DSP math - Add advanced DSP math features such as FFT, integration, and differentiation.
- HD - Hard Disk - 170Mb internal hard disk drive.
Optional Accessories
- 34 - Differential probe Add a 1 GHz (probe only) P6247 differential probe.
- 36 - Passive probe Add a 500 MHz P6139A 10X passive probe.
- 38 - Active probe Add a 4 GHz (probe only) P6249 5X, small geometry active probe.
- 39 - Differential probe Add a 1.5 GHz (probe only) P6248 small geometry active differential probe.
- 1K - Add K420 scope cart
- 1R - Rackmount kit
- 24 - Add 4 each P6139A passive probes
- 26 - Add 4 each P6245 active probes
- C3 - Three years calibration Provides three years of calibration
- D1 - Calibration data report Oscilloscope comes with a calibration data report.
- D3 - Calibration data for C3 Provides calibration data for option C3
- B2 - Hardcopy version of the programmers manual
- L1 - Substitute French user manual
- L3 - Substitute German user manual
- L5 - Substitute Japanese user manual
- L9 - Substitute Korean user manual
Standard Accessories
- 071-0473-XX - User Manual (with programmer disk 063-3060-XX)
- 071-0273-XX - TDS 600C Supplement
- 020-2313-XX - Reference Manuals
- 071-0630-XX - Technical Reference: Performance Verification and Specifications
- No probes standard
- 200-3696-01 - Front Cover
- 161-0230-01 - U.S. Power Cord
Optional Accessories
- 071-0627-XX - Service Manual
- 012-0991-01 - 1m GPIB cable
- 012-0991-00 - 2m GPIB cable
- 012-1298-00 - RS-232 cable
- 012-1250-00 - Centronics cable
- 016-0909-01 - Soft-sided carrying case
- 016-01135-00 - Transit case
- K420 - Scope cart
- 016-1236-00 - Rack Mount Kit (for field conversion)
Software Options
- LVWIN - LabVIEW for PC Windows OS
- LWCVI - LabWindows for CVI system
- LWDOS - LabWindows for DOS OS
- S3FT400 - WaveWriter AWG and waveform creation software
- TTiP - Telecommunications Templates and i-Pattern software
- WSTR31 - WaveStar waveform capture and documentation software
Links
- Tek Forum threads:
- EEVBlog Forum Threads:
- Simmconn Labs LCD replacement kits for CRT-based TDS O-scopes
- Wavestar Product Key
- TDS error log viewer
- Enabling options via GPIB interface - ko4bb.com
Pictures
-
TDS694C
-
TDS694C Front
-
TDS694C Left
-
TDS694C Rear
-
TDS694C Right
-
TDS694C Underside
-
TDS694C
-
TDS694C
-
TDS694C
-
TDS694C
-
TDS694C
-
Option 05 Internal Parts
-
Option HD Internal Parts, 2.5" Disk Version
-