P6021

From TekWiki
Revision as of 10:40, 15 June 2015 by Peter (talk | contribs) (specs, year)
Jump to navigation Jump to search
P6021 with passive termination box

The Tektronix P6021 is a current probe for oscilloscopes. It can be used with the included passive termination, a type 134 current probe amplifier, or a 3A9 or 7A14 current probe amplifier scope plug-in. Bandwidth is up to 52 MHz.

Specifications

P6021 passive P6021 + 134 P6022 passive P6022 + 134
Sensitivity 2 mA/mV or 10 mA/mV 1 mA/Div to 1 A/Div
(scope @ 50 mV/Div)
1 mA/mV or 10 mA/mV 1 mA/Div to 1 A/Div
(scope @ 50 mV/Div)
Bandwidth (-3 dB) 60 MHz @ 10 mA/mV > 40 MHz 200 MHz @ 10 mA/mV > 70 MHz
LF limit (-3 dB) 450 Hz @ 2 mA/mV
120 Hz @ 10 mA/mV
< 12 Hz 8500 Hz @ 1 mA/mV
935 Hz @ 10 mA/mV
< 100 Hz
Maximum current 15 Ap-p 6 Ap-p