3C66

From TekWiki
Revision as of 11:33, 14 August 2021 by Peter (talk | contribs) (→‎top: clean up, replaced: title=Tektronix → manufacturer=Tektronix |series=560-series scopes |type=, {{Plugin Sidebar 2 → {{Plugin Sidebar, series=560-series scopes → designers=)
Jump to navigation Jump to search
Tektronix 3C66
Carrier Amplifier plugin
Tektronix 3C66

Compatible with 560-series scopes

Produced from 1963 to 1974

Manuals
(All manuals in PDF format unless noted otherwise)
Manuals – Specifications – Links – Pictures

The Tektronix 3C66 Carrier Amplifier is a plug-in introduced in 1963 for 560-series scopes.

It is designed to amplify signals from transducers such as strain gauges, whose impedance varies based on, for example, mechanical strain. These transducers are usually connected in a bridge circuit.

The 3C66 drives the bridge with a 25 kHz "carrier" signal, which is modulated by the relative impedances of the arms of the bridge. The resulting signal is amplified and envelope-detected by the 3C66, producing a vertical deflection proportional to the measured quantity (strain, for example).

The 3C66 provides built-in variable impedances for balancing the bridge. Because the carrier is 25 kHz, the maximum bandwidth of the measured quantity is 5 kHz. This limitation is due to the settling time of the envelope detector. In addition to the vertical deflection signal, the 3C66 provides a front panel output of the measured signal.

Pictures