2465A
The Tektronix 2465A is a four-channel 350 MHz portable oscilloscope.
The 2445A and 2455A are 150 and 250 MHz versions.
CRT is the 154-0850-01.
The 2467 is the same as the 2465A, except that the 2465A uses a conventional CRT while the 2467A uses a micro-channel plate CRT. The MCP CRT enables bright traces at fast sweep rates, particularly with one-shot or low repetition rate signals.
The 2465A is from the penultimate generation of analog Tektronix scopes.
The horizontal amplifier in the 2465A was designed by Art Metz and Ken Schlotzhauer. Art Metz also worked on the triggers. Art Metz and Walt Ainsworth designed the sweeps.
Options
- Option 01 (DMM) added a 4½-digit, fully autoranging digital multimeter which measures DC and AC voltage and current, resistance, dBV, dBm, continuity, and temperature.
- Option 05 (TV) added TV (back-porch) clamp circuitry to the Channel 2 input and TV trigger coupling modes, allowing selection of either horizontal or vertical sync pulses to obtain horizontal-line-sync or field-sync pulse triggering.
- Option 06 (Counter/Timer/Trigger) allows precision time-interval measurement, event and frequency counting, delay-by-events triggering, and logic triggering.
- Option 09 added option 06, the CTT, plus a 17-bit P6407 word recognizer probe.
- Option 10 added a GPIB interface for remote control.
- Option 11 added two probe-power connectors on the rear panel of the instrument. Only shown in the 1987 catalogue.
Key Specifications
— 2445 — | |
Bandwidth | 150 MHz |
— 2455A — | |
Bandwidth | 250 MHz |
— 2465A — | |
Bandwidth | 350 MHz |
— 2467 — | |
Bandwidth | 350 MHz |
— Common — | |
Sweep Rate | 500 ps/div |
Channels | Four independent channels |
Vertical | 2 mV/div vertical sensitivity |
Cursors | Delta Volts and Delta Time Cursors |
CRT Readout | Scale Factors, Trigger Level, Voltage, Time, Frequency, Phase and Ratio Measurements and Mode Indicators |
Trigger | Advanced Triggering with "Hands Off" Auto Level Triggering |
Trigger Bandwidth | 500 MHz min. |
Input Impedance | 50 Ω/1 MΩ inputs with 50 Ω protection |
Probes | Two or four P6136 ×10 probes, 1.3 m |