502/Repairs

Revision as of 07:51, 8 November 2019 by Peter (talk | contribs)

Supply out of regulation

Symptom: +350 V supply out of regulation (~300 V)
Root cause: C751 10 nF "Bumble Bee" leaky
Solution: Replace C751

HV very low

Symptom: HV very low, oscillator tube V800 gets very hot
Root cause: Black Beauty capacitors in HV circuit leaky
Solution: Replace all 6.8 nF HV caps

No sweep at slower speeds

Symptom: In 1 ms/Div and slower, no sweep − trace stationary on left
Root cause: Bumble Bee capacitors in holdoff circuit leaky
Solution: Replace C180B-D