PG508

Revision as of 10:43, 6 June 2021 by Peter (talk | contribs)

The Tektronix PG508 is a 50 MHz pulse generator plug-in for the TM500 system.

Tektronix PG508
50 MHz pulse generator
Tektronix PG508

Produced from 1976 to 1993

Manuals
(All manuals in PDF format unless noted otherwise)


Pulses can be triggered by an external input, a manual trigger button, or an internal period generator (optionally gated by the trigger input). The trigger signal can be undelayed, delayed by a selectable time, or both (in which case double pulses are generated). The pulse duration, leading and trailing edge transition times, high- and low-level amplitude can be controlled independently.

Period, delay, duration, and transition time switches each feature a custom position where a user-supplied internal capacitor determines the timing.

Key Specifications

Period external, or internal <20 ns to >200 ms in 7 decade steps plus variable; ≥200 ms possible in custom range
Jitter <0.1% +50 ps
Delay Time <10 ns to >100 ms in 7 decade steps plus custom position and variable control; ≥100 ms possible in custom range
Pulse Duration square, or <10 ns to >100 ms in 7 decade steps plus custom position and variable control; ≥100 ms possible in custom range
Transition time Ranges 5 ns to 500 μs in decade steps plus custom position; separate  ×1 to ×100 variable controls for leading and trailing edge (5 ns to 50 ms effective)
Output level High and low levels adjustable independently in −20 V to +20 V range, limited to max. 20 Vp-p / min. 1 Vp-p (open circuit), 50 Ω source impedance (−10 V to +10 V, 0.5 to 10 Vp-p into 50 Ω)
Trigger/Gate input Sensitivity 80 mVp-p to ≥10 MHz, 250 mVp-p to ≥50 MHz at 50 Ω impedance, max. ±5 Vpeak; 1 MΩ // 20 pF optionally selectable (internal switch), max. ±20 Vpeak

Rear Interface

(right-hand plug-in slot as viewed from front)

  • 27B/28B(GND) Trig output (complement polarity installed; for normal polarity, front panel input requires optional cable and front output disconnection) [note error on manual p.1-12; table 1-13 is correct]
  • 24B/25B(GND) Trig input (with optional cable, front panel input must be disconnected)
  • 25A/26A(GND) Amplitude Monitor (from output via 27 kΩ)
  • 22A External Low Level Control Input (requires internal jumper and trim)
  • 22B External High Level Control Input (requires internal jumper and trim)

Custom connection solder pads ae available on the left plug-in slot, which is otherwise used only for hte associated pass transistors in the mainframe.

References

  • Designs by the Masters – ±20 V, 5 ns, 50 Ω Amplifier (detailed discussion of the PG508 output stage). Horowitz & Hill, Art of Electronics - The x-Chapters, p.150+

Pictures