DC504

Revision as of 13:28, 24 April 2023 by Peter (talk | contribs)

The Tektronix DC504 is a 80 MHz, 5-digit frequency counter plug-in for the TM500 system.

Tektronix DC504
80 MHz, 5-digit frequency counter
Tektronix DC504

Produced from 1975 to 1983

Manuals
(All manuals in PDF format unless noted otherwise)

It was superseded by the DC504A in 1984.

Key Specifications

Frequency Range DC (AC coupled: 10 Hz) to at least 80 MHz
Sensitivity 20 mVRMS sine wave below 15 MHz, 35 mVRMS to 50 MHz, derated down to 175 mVRMS at 80 MHz
Input impedance 1 MΩ // 20 pF
Trigger Level Range −1.5 V to +1.5 V
Frequency Resolution kHz ranges: 0.1 Hz; 1 Hz and 10 Hz (7 digit resolution possible in overflow kHz position); MHz ranges: 100 Hz, 1 kHz (9 digit resolution possible in overflow kHz position)
Period resolution ms ranges: 1 µs, 10 µs; s ranges: 10 ms, 1 ms, 0.1 ms
Display Time Variable ~0.1 s ... ~10 s and HOLD mode
Standard Time Base 1 MHz, ±1×10-5 from 0°C to +50°C, ±1×10-5 per month, Adjustable to within 1×10-7
Opt. 1 Time Base 5 MHz, ±1×10-7 from 0°C to +50°C, ±1×10-7 per month, Adjustable to within 1×10-9

An internal "RPM" mode switch stretches gate times sixfold, giving a longest gate time of 1 minute with a display scaled in revolutions per minute.

Rear Interface

  • 28A − Hold
  • 28B − Gate Out, Totalize Start/Stop
  • 27B − Decimal point
  • 26A − /Reset
  • 25A − TS1 (digit select 1, MSD)
  • 24B − Scan clock out
  • 24A − TS2 (digit select 2)
  • 23B − Overflow
  • 23A − TS3 (digit select 3)
  • 22A − TS4 (digit select 4)
  • 21B − BCD out 2
  • 21A − TS5 (digit select 5, LSD)
  • 20B − BCD out 8
  • 20A − BCD out 4
  • 19B − Latch Out (Data Good)
  • 19A − BCD out 1
  • 16A − Signal input (GND on 17A)
  • 14A − External Clock (GND on 15A)

Pictures

DC504 (1975−1983)