Steps cannot be adjusted
Problem:
Number of steps could not be adjusted.
Root cause:
resistive element of R100 (steps potentiometer) was cracked into two halves
Solution:
Replace R100
--
Peter
(
talk
) 02:03, 4 May 2019 (PDT)
Pushbutton switch repairs
See
https://amplifier.cd/Test_Equipment/Tektronix/Tektronix_7000_series_special/7CT1N_SchalterRep.pdf
(in German, with photos)