5T1A: Difference between revisions

209 bytes added ,  23 September 2014
template, cat
No edit summary
(template, cat)
Line 1: Line 1:
The Tektronix 5T1A is a timing plug-in [[introduced in 1963]] for the [[661]]  
{{Plugin Sidebar 2|
[[sampling oscilloscope]].
title=Tektronix 5T1A |
summary=Timing plugin |
image=5t1a front.jpg |
caption=5T1A front |
series=[[661|661 Sampling Scope]] |
introduced=1963 |
discontinued=(?) |
manuals=
* [http://w140.com/kurt/tektronix_5t1a.pdf Tektronix 5T1A Manual (PDF)]
* [http://w140.com/tek_fcp/tek_type_5t1a_factory_cal_proc.pdf Tektronix 5T1A Field Recalibration Procedure (PDF)]
}}
The '''Tektronix 5T1A''' is a timing plug-in [[introduced in 1963]] for the [[661]]  
[[sampling oscilloscope]].  
 
It is an improved version of the [[5T1]].  The job of the 5T1A is to produce three signals:
It is an improved version of the [[5T1]].  The job of the 5T1A is to produce three signals:
the sampling pulse, the horizontal sweep, and the blanking signal.
the sampling pulse, the horizontal sweep, and the blanking signal.
Line 7: Line 20:
* internally from the trigger pick-off in a [[4S1]] plug-in
* internally from the trigger pick-off in a [[4S1]] plug-in
* externally via a GR-874 connector on the front panel of the 5T1A
* externally via a GR-874 connector on the front panel of the 5T1A
* from the calibration oscillator in the 661, via the muliti-pin plug-in connector   
* from the calibration oscillator in the 661, via the multi-pin plug-in connector   
* free-running  
* free-running  
Each of these modes is suited to some measurement scenarios.   
Each of these modes is suited to some measurement scenarios.   
Line 14: Line 27:
through the 661, connecting the sampling unit to the timing unit.
through the 661, connecting the sampling unit to the timing unit.


Triggering in the 5T1A is accomplished using five [[1N3129]] 20mA [[tunnel diodes]].
Triggering in the 5T1A is accomplished using five [[1N3129]] 20 mA [[tunnel diodes]].
 
* [http://w140.com/kurt/tektronix_5t1a.pdf Tektronix 5T1A Manual (PDF)]
* [http://w140.com/tek_fcp/tek_type_5t1a_factory_cal_proc.pdf Tektronix 5T1A Field Recalibration Procedure (PDF)]


==Pictures==
<gallery>
<gallery>
Image:5t1a front.jpg
File:5t1a front.jpg
Image:5t1a right.jpg
File:5t1a right.jpg
Image:5t1a left.jpg
File:5t1a left.jpg
Image:5t1a top.jpg
File:5t1a top.jpg
Image:5t1a bottom.jpg
File:5t1a bottom.jpg
Image:5t1a coax interconnect.jpg
File:5t1a coax interconnect.jpg
Image:5t1a rear connector.jpg
File:5t1a rear connector.jpg
Image:5t1a_trigger2.png|Trigger schematic
File:5t1a_trigger2.png|Trigger schematic
File:5t1a fastramp.png|Fast Ramp schematic
File:5t1a fastramp.png|Fast Ramp schematic
File:5t1a staircase gen.png|Staircase Generator schematic
File:5t1a staircase gen.png|Staircase Generator schematic