7A13: Difference between revisions

11 bytes added ,  16 September 2018
m
no edit summary
mNo edit summary
Line 24: Line 24:
In addition, this voltage is brought out through a front panel connector so it can be measured externally.
In addition, this voltage is brought out through a front panel connector so it can be measured externally.


In differential mode, a +/-10 V common mode signal can be present at the inputs without attenuation.   
In differential mode, a ±10 V common mode signal can be present at the inputs without attenuation.   
Either input can be switched to the comparison voltage,  
Either input can be switched to the comparison voltage,  
which is settable to four digits by a 10-step switch and a 10-turn potentiometer.   
which is settable to four digits by a 10-step switch and a 10-turn potentiometer.   
Line 36: Line 36:
{{Spec | Rise time | 3.5 ns }}
{{Spec | Rise time | 3.5 ns }}
{{Spec | Deflection factor | 1 mV/Div – 5 V/Div (1–2–5 sequence) }}
{{Spec | Deflection factor | 1 mV/Div – 5 V/Div (1–2–5 sequence) }}
{{Spec | Common Mode range | at least +10 V / -10 V from 1 mV/Div to 5 mV/Div, +100 V / -100 V from 10 mV/Div to 50 mV/Div, +500 V / -500 V from 100 mV/Div to 5 V/Div }}
{{Spec | Common Mode range | at least +10 V / −10 V from 1 mV/Div to 5 mV/Div, +100 V / −100 V from 10 mV/Div to 50 mV/Div, +500 V / −500 V from 100 mV/Div to 5 V/Div }}
{{Spec | Overdrive Recovery | to within 2 mV in 1µs (at 1 mV/Div) }}
{{Spec | Overdrive Recovery | to within 2 mV in 1µs (at 1 mV/Div) }}
{{Spec | CMRR | at least 10,000:1 for 10 V<sub>p-p</sub> or less, 100 kHz to 1 MHz, decreasing to 500:1 at 10 MHz with 1 V<sub>p-p</sub>, 200:1 at 20 MHz with 1 V<sub>p-p</sub> }}
{{Spec | CMRR | at least 10,000:1 for 10 V<sub>p-p</sub> or less, 100 kHz to 1 MHz, decreasing to 500:1 at 10 MHz with 1 V<sub>p-p</sub>, 200:1 at 20 MHz with 1 V<sub>p-p</sub> }}
{{Spec | Input impedance | 1 MΩ // 20 pF }}
{{Spec | Input impedance | 1 MΩ // 20 pF }}
{{Spec | Comparison voltage | 0 V — +/-10 V }}
{{Spec | Comparison voltage | −10 V to +10 V }}
{{Spec | Vc reading accuracy |  
{{Spec | Vc reading accuracy |  
Mechanical version: 0.1% of reading + 5 mV
Mechanical version: 0.1% of reading + 5 mV
Line 50: Line 50:
The power consumption of a 7A13 was measured to be:
The power consumption of a 7A13 was measured to be:
* +50 V: 75 mA
* +50 V: 75 mA
* -50 V: 66 mA
* −50 V: 66 mA
* +15 V: 238 mA
* +15 V: 238 mA
* -15 V: 204 mA
* −15 V: 204 mA
* +5 V (logic): 279 mA
* +5 V (logic): 279 mA
* +5 V (lights): 228 mA
* +5 V (lights): 228 mA
Line 81: Line 81:
The plug-in can still be used when the counter fails, by using an
The plug-in can still be used when the counter fails, by using an
external voltmeter to monitor the comparison voltage, V<sub>c</sub>.
external voltmeter to monitor the comparison voltage, V<sub>c</sub>.
Later 7A13 plug-ins use an LED readout instead of the mechanical counter.
Later 7A13 plug-ins use an LED readout instead of the mechanical counter.
The LED readout is much less problematic.
The LED readout is much less problematic.