P6048: Difference between revisions

58 bytes removed ,  1 December 2023
no edit summary
(added usage to description)
No edit summary
Line 6: Line 6:
|caption=Tektronix P6048
|caption=Tektronix P6048
|for=1 MΩ scope inputs
|for=1 MΩ scope inputs
|introduced=(?)
|introduced=1967
|discontinued=(?)
|discontinued=(?)
|manuals=
|manuals=
* add manual
* add manual
}}
}}
 
The '''Tektronix P6048''' (010-0215-00) is a ×10, 1 kΩ, ≤1 pF passive, low-capacitance probe that is switchable for AC or DC coupling.  
The '''Tektronix P6048''' (010-0215-00) is a ×10, 1 kΩ, ≤1 pF passive probe that is switchable for AC or DC coupling. It was originally designed for use with the Type [[454]] and the Type [[647A]], but it can be used with any oscilloscope with suitable input impedance.
It was originally designed for use with the Type [[454]] and the Type [[647A]], but it can be used with any oscilloscope with suitable input impedance.


{{BeginSpecs}}
{{BeginSpecs}}
{{Spec | Bandwidth | DC (AC Coupled: ≤7 kHz) to 140 MHz }}
{{Spec | Input impedance | 1 kΩ // ≤1 pF }}
{{Spec | Input voltage | max. 20 V DC plus peak AC; (AC Coupled: max. 200 V<sub>DC</sub> plus 20 V<sub>AC</sub>) }}
{{Spec | Oscilloscope input impedance | 1 MΩ // 14-21 pF }}
{{Spec | Cable length | 6 ft }}
{{Spec | Cable length | 6 ft }}
{{Spec | Probe input impedance | 1 kΩ // ≤1 pF }}
{{Spec | Oscilloscope input impedance | 1 MΩ // 14-21 pF }}
{{Spec | Bandwidth, DC Coupled | DC to 140 MHz }}
{{Spec | Max voltage, DC Coupled | 20 V (DC plus peak AC) }}
{{Spec | Bandwidth, AC Coupled | ≤7 kHz to 140 MHz }}
{{Spec | Max voltage, AC Coupled | 200 V<sub>DC</sub> plus 20 V<sub>AC</sub> }}
{{EndSpecs}}
{{EndSpecs}}


Line 36: Line 34:


[[Category:1 MΩ Oscilloscope probes]]
[[Category:1 MΩ Oscilloscope probes]]
[[Category:Low capacitance probes]]
[[Category:Low-capacitance probes]]