DC504
The Tektronix DC504 is a 100 MHz, 5-digit frequency counter plug-in for the TM500 system.
The DC504A successor, introduced in 1984, has 6 digits.
Key Specifications
Frequency Range | 0 Hz (AC coupled: 10 Hz) to at least 80 MHz |
---|---|
Sensitivity (sine wave) | 20 mVRMS below 15 MHz, 35 mVRMS to 50 MHz, derated down to 175 mVRMS at 80 MHz |
Input impedance | 1 MΩ // 20 pF |
Trigger Level Range | −1.5 V to +1.5 V |
Maximum Frequency Resolution | kHz ranges: 0.1 Hz; 1 Hz and 10 Hz (7 digit resolution possible in overflow kHz position); MHz ranges: 100 Hz, 1 kHz (9 digit resolution possible in overflow kHz position) |
Maximum period resolution | ms ranges: 1 µs, 10 µs; s ranges: 10 ms, 1 ms, 0.1 ms |
Trigger Error | 0.5% of one cycle at min. trigger sensitivity |
Display Time | Variable ~0.1 s ... ~10 s and HOLD mode |
— Internal Standard Time Base (1 MHz) — | |
Stability | 0°C to +50°C after 30 min warm up: 1×10-5 |
Long Term Drift | 1×10-5 per month |
Accuracy | Adjustable to within 1×10-7 |
— Internal Time Base Option 1 (5 MHz) — | |
Stability | 0°C to +50°C after 30 min warm up: 1×10-7 |
Long Term Drift | 1×10-7 per month |
Accuracy | Adjustable to within 5×10-9 |
An internal "RPM" mode switch stretches gate times sixfold., giving a longest gate time of 1 minute with a display scaled in revolutions per minute.
Rear Interface
- 28A − Hold
- 28B − Gate Out, Totalize Start/Stop
- 27B − Decimal point
- 26A − /Reset
- 25A − TS1 (digit select 1, MSD)
- 24A − TS2 (digit select 2)
- 23B − Overflow
- 23A − TS3 (digit select 3)
- 22A − TS4 (digit select 4)
- 21B − BCD out 2
- 21A − TS5 (digit select 5, LSD)
- 20B − BCD out 8
- 20A − BCD out 4
- 19B − Latch Out (Data Good)
- 19A − BCD out 1
- 16A − Signal input
- 14A − External Clock
Pictures
DC504 (1975−1983)
-
DC504
-
DC504
-
DC504
-
DC504
-
DC504
-
DC504
-
DC504 inside; component side
-
DC504 inside; copper side
DC504A (1984−1993)
-
DC504A
-
DC504A
-
DC504A left internal
-
DC504A right internal
-
DC504A 3/4 view