7CT1N/Repairs
Steps cannot be adjusted
- Problem: Number of steps could not be adjusted.
- Root cause: resistive element of R100 (steps potentiometer) was cracked into two halves
- Solution: Replace R100
- --Peter (talk) 02:03, 4 May 2019 (PDT)
Pushbutton switch repairs
- See https://amplifier.cd/Test_Equipment/Tektronix/Tektronix_7000_series_special/7CT1N_SchalterRep.pdf (in German, with photos)