160: Difference between revisions

1,512 bytes added ,  10 July 2022
no edit summary
No edit summary
No edit summary
(17 intermediate revisions by 4 users not shown)
Line 1: Line 1:
[[File:Tek_160a_360_161_162_trace.jpg|thumb|350px|right]]
{{Oscilloscope Sidebar
The '''Tektronix 160 series''' is a modular oscilloscope made from the mid-1950s
|manufacturer=Tektronix
(schematics drawn in [[introduced in 1953|1953]]) to the late 1960s (in 1969 catalog).
|model=160
|series=160
|summary=Modular Oscilloscope
|image=Tek_160a_360_161_162_trace.jpg
|caption=160A 360 161 162
|introduced=1952
|discontinued=(?)
|designers=
|manuals=
* [[Media:070-220.pdf|Tektronix 160-series Manual]] (PDF)
* [https://w140.com/tek_360_160_irb.pdf Tektronix 160-series Instrument Reference Book (PDF, OCR, 210MB!)]
* [[Media:Tek 160a fcp.pdf|Tektronix 160a Factory Calibration Procedure (PDF, OCR)]]
}}
The '''Tektronix 160 series''' is a modular instrument made from the mid-1950s (schematics drawn in [[introduced in 1953|1953]]) to the late 1960s (in 1969 catalog). The catalog describes them as instruments designed to generate timed pulses of variable amplitude and width for use in nerve stimulation/neurophysical experiments.


A 160 series system typically includes a Type 160 power supply,  
A 160 series system typically includes a Type 160 power supply, a [[360|Type 360 indicator unit]], and one or more of the [[161]], [[162]], and [[163]] trigger and sweep modules.
a [[360|Type 360 indicator unit]], and one or more of the  
[[161]], [[162]], and [[163]] trigger and sweep modules.
There is also a single-unit power supply, the [[126]].
There is also a single-unit power supply, the [[126]].


Each module is the size of a small shoe box.  Power connections are made behind  
Each module is the size of a small shoe box.  Power connections are made behind the modules using [[W160|Type W160]] cables that have [[octal connector]]s.   
the modules using [[W160|Type W160]] cables that have [[octal connector]]s.   
The power cables can be connected in a star topology (Type 160 in the center) or can be daisy-chained using the loop-through connection on the back of each module.  
The power cables can be connected in a star topology (Type 160 in the center)  
or can be daisy-chained using the loop-through connection on the back of each module.  


Signal connections are made on the front, typically with banana plugs.   
Signal connections are made on the front, typically with banana plugs.   


In a typical setup, the input signal is fed through a splitter to the Y-input of the  
In a typical setup, the input signal is fed through a splitter to the Y-input of the 360 and the trigger input of the 161.   
360 and the trigger input of the 161.  The 161 generates a trigger pulse that controls a 162,  
The 161 generates a trigger pulse that controls a 162, which generates the horizontal ramp for the sweep.   
which generates the horizontal ramp for the sweep.  This ramp signal is sent to the 360 horizontal input.   
This ramp signal is sent to the 360 horizontal input.   


The signals on the front panel of the 160-series modules are all single-ended.
The signals on the front panel of the 160-series modules are all single-ended.


According to the May 1952 issue of Tek Talk (page 6),  
According to the May 1952 issue of Tek Talk (page 6), the 160 Series entered limited production in April of 1952.  
the 160 Series entered limited production in April of 1952.  


{{MissingSpecs}}
* [[Media:Tek_160-1953_Catalog.pdf |160 Description from 1953 catalog (PDF)]]
==Manuals==
 
* [http://w140.com/tek_160.pdf Tektronix 160-series Manual (PDF)]
{{BeginSpecs}}
* [http://w140.com/tek_360_160_irb.pdf Tektronix 160-series Instrument Reference Book (PDF, OCR)]
{{SpecGroup|Type 160 Power Supply}}
{{Spec | +300 V output | DC, unregulated, 170 mA max}}
{{Spec | +225 V output | DC, regulated, 125 mA max }}
{{Spec | +150 V output | DC, regulated, 5 mA max }}
{{Spec | −170 V output | DC, regulated, 125 mA max}}
{{Spec |  6.3 V output | AC, unregulated, 10 A max }}
{{SpecGroup|Type 160A Power Supply}}
{{Spec | +300 V output | DC, unregulated, 250 mA max}}
{{Spec | +225 V output | DC, regulated, 175 mA max }}
{{Spec | +150 V output | DC, regulated, 15 mA max }}
{{Spec |  +70 V output | DC, unregulated ''max load?''}}
{{Spec | −170 V output | DC, regulated, 125 mA max}}
{{Spec |  6.3 V output | AC, unregulated, 20 A max }}
{{EndSpecs}}


==Internals==
==Internals==
Line 53: Line 74:
[[6080]] dual-triode in parallel to regulate the +225 V output,  
[[6080]] dual-triode in parallel to regulate the +225 V output,  
and two parallel [[12B4]] triodes to regulate the −170 V output.
and two parallel [[12B4]] triodes to regulate the −170 V output.
==Links==
* [https://vintagetek.org/160-series-instruments/ 160 @ Vintage Tek]


==Pictures ==
==Pictures ==
Line 69: Line 93:
Tek 160 system 6.jpg
Tek 160 system 6.jpg
Tek 160 system 7.jpg
Tek 160 system 7.jpg
Tek_160A_Front.jpeg | 160A Power supply, front
Tek_160A_Front1.jpeg | 160A Power supply
Tek_160A_Back1.jpeg | 160A Power supply
Tek_160A-Rear.png| 160A Power supply, rear
Tek_160A-RHS.jpeg  | 160A Power supply, RHS
Tek_160A_Underside.jpeg | 160A Power supply, underside
</gallery>
</gallery>


[[Category:Introduced in 1952]]
{{Parts|160}}
 
[[Category:160 system]]
[[Category:160 system]]