2440: Difference between revisions

2,638 bytes added ,  18 April 2022
no edit summary
No edit summary
No edit summary
(36 intermediate revisions by 5 users not shown)
Line 1: Line 1:
{{Oscilloscope Sidebar|
{{Oscilloscope Sidebar  
title=Tektronix 2440 |
|manufacturer=Tektronix
image=2440_1.jpg |
|series=2400-series scopes
caption=Tektronix 2440  |
|model=2440  
introduced=1988 |
|image=2440_1.jpg  
discontinued=(?) |
|caption=Tektronix 2440   
summary=300 MHz, 500 MS/s 2-ch digital scope |
|introduced=1988  
manuals=
|discontinued=(?)  
* [http://w140.com/tek_2440_service.pdf Tektronix 2440 Manual (complete, B014064 and below) (PDF)]
|summary=300 MHz, 500 MS/s 2-ch digital scope  
* [http://w140.com/tek_2440_programmer_man.pdf Tektronix 2440 Programmer Manual (PDF)]
|designers=
|manuals=
* [http://w140.com/tek_2440_service.pdf Tektronix 2440 Manual (complete, B014064 and below) (PDF, OCR)]
* [http://w140.com/tek_2440_programmer_man.pdf Tektronix 2440 Programmer Manual (PDF, OCR)]
* [http://w140.com/tek_2440.pdf Tektronix 2440 Manual (without schematics) (PDF)]
* [http://w140.com/tek_2440.pdf Tektronix 2440 Manual (without schematics) (PDF)]
* [[Media:Tek-2430A-2432A-2440-catalog.pdf|2430A/2432A/2440 catalog page (PDF)]]
* [[Media:2430A-2432A-2440-catalog.pdf|2430A/2432A/2440 catalog page (PDF, OCR)]]
}}
}}
The '''Tektronix 2440''' is a two-channel 300 MHz digital sampling oscilloscope from the late 1980s.
The '''Tektronix 2440''' is a two-channel 300 MHz, 500 MS/s digital sampling oscilloscope from the late 1980s.
The maximum sample rate is 500 megasamples per second, per channel


It uses CCDs (essentially, analog shift registers) to store input samples at high speed and a single 8 bit flash A/D converter to digitize the time-multiplexed CCD output signals at 4 MS/s. 


'''WARNING'''
<blockquote>
Operation of the 2440 (and 2432 and 2430):
'''WARNING:'''<br />
Operation of the 2440 (and 2432 and 2430): A/D-converter and CCD hybrids may suffer irreparable damage within a few minutes if operated out of the metal enclosure without extra cooling.
</blockquote>


AD-converter and CCD hybrids may suffer irreparable damage within a few minutes if operated out of the metal enclosure without extra cooling.
{{BeginSpecs}}
'''WARNING'''
{{Spec | Bandwidth | 300 MHz (Limit: 20, 100, Full) }}
{{Spec | Sampling rate | 500 MSa/s each channel with simultaneous acquisition }}
{{Spec | Deflection | 2 mV/div to 5 V/div in 1-2-5 sequence }}
{{Spec | Auto scale factor | On-Screen Readout indicates probe tip deflection factors for ×1, ×10, ×100 and ×1000 probes }}
{{Spec | Input impedance| 1 MΩ // 15 pF }}
{{Spec | Sweep speeds | 2 ns/div to 5 s/div in 1-2-5 sequence (Modes A, A Intensified and B)}}
{{Spec | Auto measure| Simultaneously measures up to four parameters on one or more displayed waveforms, updated at 3 Hz intervals or display a snapshot of 20 parameters of waveform target }}
{{Spec | Acquisition modes| Normal, Envelope (glitch capture), Average }}
{{Spec | Display modes| CH1, CH2, invert, add, multiply, X-Y }}
{{Spec | Cursors  | Volts, Time, Volts At Time, 1/Time, Slope }}
{{Spec | Functions | A Mode - Auto Level, Auto/Roll, Normal and Single Seq; B Mode - Trigger After Delay, Runs After Delay, 1K Record Length and more }}
{{Spec | Interface | GPIB }}
{{Spec | Probes    | Two passive [[P6137]] 400 MHz ×10 voltage probes, 1.3 m }}
{{Spec | Power    | 90 to 132 V<sub>AC</sub> or 80 to 250 V<sub>AC</sub>, 48 to 440 Hz; 160 W }}
{{Spec | Features  |
* Autoprobe Function With [[P6137]] Probe
* 300 MHz X-Y bandwidth at probe tip
* Automatic measurements
* extensive triggering capabilities
* Printer/Plotter Output
* On-screen HELP text describing every front-panel control
}}
{{Spec | Options |
* 03 - Word Recognizer ([[P6407]])
* 05 - Video Waveform Measurement System
* 11 - Two [[LEMO S-series connector|probe-power connectors]] on the rear panel
}}
{{EndSpecs}}
 
==Links==
* [https://hohlerde.org/rauch/en/elektronik/geraete/tek2440/  Tektronix 2440 internals & repair @ hohlerde.org]


{{MissingSpecs}}
==Internals==
The 2440 employs several processors − an [[Motorola 6809|MC68B09]] main CPU controls the instrument, a custom 16-bit waveform processor performs signal computations, and an [[Motorola 6805|MC6805]] microcontroller handles the front panel interface.  The GPIB Interface is implemented with a [[TMS9914]] controller.


The power supply consists of a buck-type pre-regulator followed by a push-pull inverter and linear post-regulators (except for the +5 V digital supply rail).
CRT is a [[154-0850-01]].
==Pictures==
<gallery>
<gallery>
Tek 2440 1.jpg
Tek 2440 1.jpg
Line 30: Line 71:
Tek 2440 4.jpg
Tek 2440 4.jpg
Tek 2440 5.jpg
Tek 2440 5.jpg
Tek 2440 rear2.jpg
2440 1A.jpg
2440 1B.jpg
</gallery>
</gallery>


[[Category:2000 series scopes]]
{{CRTs|2440}}
{{Custom ICs|2440}}
 
 
[[Category:2400 series scopes]]
[[Category:Digital storage scopes]]
[[Category:Digital storage scopes]]


[[Category:GPIB interface]]
[[Category:GPIB interface]]