{{Oscilloscope Sidebar |
{{Instrument Sidebar  
title=Tektronix 2755AP |
|class=Spectrum Analyzer
summary=Spectrum Analyzer 10 kHz to 21 GHz |
|manufacturer=Tektronix  
image= Tek_2755P_Waveform_image.jpg |
|model=2755AP  
caption=Tektronix 2755AP |
|summary=21 GHz Spectrum Analyzer  
introduced=1987 |
|image= Tek_2755P_Waveform_image.jpg  
discontinued=1993 |
|caption=Tektronix 2755AP  
manuals=
|introduced=1987  
Need Operator’s, Service, and Programmers Manuals
|discontinued=1993  
* [[Media: Tek_2755_Catalog_Spec_1987.pdf| Tektronix 2756 Introduction Spec (PDF)]]
|manuals=
* [[Media: Tek_2755_Catalog_Spec_1991.pdf| Tektronix 2756 Final Spec (PDF)]]  
* Operator, Service, and Programmer Manuals needed [[Category:Manual needed]]
* [[Media:Tek_2755_Catalog_Spec_1987.pdf| Tektronix 2755 Introduction Spec (PDF, OCR)]]
* [[Media:Tek_2755_Catalog_Spec_1991.pdf| Tektronix 2755 Final Spec (PDF, OCR)]]  
}}
}}
The '''Tektronix 2755AP''' is a spectrum analyzer with a frequency range of 10 kHz to 21 GHz in coax, and up to 325 GHz with external waveguide mixers.  The '''P''' suffix designation indicates GPIB '''P'''rogrammability.  The minimum resolution bandwidth is 100 Hz, and provides measurement resolution proportional to the frequency accuracy or span.  In addition to conventional digital storage features, non-volatile memory (NVRAM) stores up to 9 separate waveforms with their readouts and markers, for later recall for additional analysis and comparison, and 10 control settings.  Also, store up to 39 preselector peaks and 12 external band peaks.  The instrument can selectively count one particular signal out of several that may be present at its input.
The '''Tektronix 2755AP''' is a spectrum analyzer with a frequency range of 10 kHz to 21 GHz in coax, and up to 325 GHz with external waveguide mixers.  The '''P''' suffix designation indicates GPIB '''P'''rogrammability.  The minimum resolution bandwidth is 100 Hz, and provides measurement resolution proportional to the frequency accuracy or span.  In addition to conventional digital storage features, non-volatile memory (NVRAM) stores up to 9 separate waveforms with their readouts and markers, for later recall for additional analysis and comparison, and 10 control settings.  Also, store up to 39 preselector peaks and 12 external band peaks.  The instrument can selectively count one particular signal out of several that may be present at its input.


Line 23: Line 24:


{{BeginSpecs}}
{{BeginSpecs}}
{{Spec | Frequency Range |  
{{Spec | Frequency | 10 kHz to 21 GHz, up to 325 GHz with external waveguide mixers }}
* Coaxial Input Bands: 10 kHz to 21 GHz
{{Spec | Frequency Span | 100 Hz/div to 10 GHz/div in 1-2-5 sequence (plus 0 Hz and MAX) }}
* External Waveguide mixers: 18 kHz to 325 GHz }}
{{Spec | Resolution Bandwidth | 6 dB bandwidths from 100 Hz to 3 MHz in decade steps }}
{{Spec | Frequency Span Range (plus 0 Hz and MAX) | 100 Hz/div to 10 GHz/div in 1-2-5 sequence }}
{{Spec | Resolution Bandwidth Range | 6 dB bandwidths from 100 Hz to 3 MHz; 100 Hz to 1 MHz in decade steps }}
{{Spec | RF Input impedance | 50 Ω }}
{{Spec | RF Input impedance | 50 Ω }}
{{Spec | Maximum Safe Input Power |
{{Spec | Maximum Safe Input Power | 1 W (+30 dBm) CW, 75 W peak (1 µs pulse, 0.1% duty factor) }}
* CW Power: 1 Watt (+30 dBm);
{{Spec | RF Attenuator | 0 dB to 60 dB, 10 dB steps }}
* Pulse Power: 75 W peak (1 µS pulse width, 0.1% duty factor) }}
{{Spec | Reference Level | -117 dBm to +40 dBm (+30 dBm maximum safe input) }}
{{Spec | External Mixer Input | 50Ω for IF frequency inputs from external mixers covering 18 to 325 GHz }}
{{Spec | RF Attenuator Range | 0 dB to 60 dB, 10 dB steps }}
{{Spec | Reference Level Range | -117 dBm to +40 dBm (+30 dBm maximum safe input) }}
{{Spec | LO Output Power (2 to 6 GHz) | 1st LO: +7.5 dBm to +15 dBm; 2nd LO: -22 dBm to +15 dBm; Must be terminated into 50 Ω when they are not connector to an external device }}
{{Spec | LO Output Power (2 to 6 GHz) | 1st LO: +7.5 dBm to +15 dBm; 2nd LO: -22 dBm to +15 dBm; Must be terminated into 50 Ω when they are not connector to an external device }}
{{Spec | Sweep Speed Range | 5 s to 2 µs in 1, 2, 5 sequence (10 s/div in auto) }}
{{Spec | Sweep Speed | 5 s to 2 µs in 1, 2, 5 sequence (10 s/div in auto) }}
{{Spec | Video Bandwidth Range | 0.3 Hz to 30 kHz }}
{{Spec | Video Bandwidth | 0.3 Hz to 30 kHz }}
{{Spec | Triggering Modes | Internal, External, Line, Free Run }}
{{Spec | Displayed Average Noise | −125 dBm }}
{{Spec | Displayed Average Noise | −125 dBm }}
{{Spec | Display Dynamic Range | 90 dB }}
{{Spec | Dynamic Range | Display 90 dB, Compression to noise 134 dBm }}
{{Spec | Dynamic Range (Compression to noise) | 134 dBm }}
{{Spec | Calibrator (Cal out) | 50 Ω, -20 dBm ±0.3 dB at 100 MHz }}
{{Spec | Calibrator (Cal out) | 50Ω, -20 dBm ±0.3 dB at 100 MHz }}
{{Spec | Power | 90 − 132 V<sub>AC</sub>, 48 to 448 Hz; 180 – 250 V<sub>AC</sub>, 48 to 72 Hz.  At 115 V<sub>AC</sub>, 60 Hz, 210 W max with all options }}
{{Spec | Included Accessories |Operator’s Manual; Programmer’s Manual; 6-ft, 50Ω coaxial cable, N-N; 18-inch, 50Ω coaxial cable, BNC-BNC; N male to BNC female adapter; rear connector shield; power cord, power cord clamp, and spare fuses; CRT filter set consisting of amber and gray light filters plus mesh filter }}
{{Spec | Weight | 27 kg (60 lbs) }}
{{Spec | Weight | 27 kg (60 lbs) }}
{{Spec | Power | 90 − 132 V<sub>AC</sub>, 48 to 448 Hz; 180 – 250 V<sub>AC</sub>, 48 to 72 Hz.  At 115 V<sub>AC</sub>, 60 Hz, 210 W max with all options }}
{{Spec | Operating Atmospherics | Temperatures: 0 °C to +50 °C; Humidity: 95% below +30 °C, 75% above +30 °C, 45% above +40 °C; Altitude: Up to 3 km (10,000 ft) }}
{{Spec | GPIB Characteristics | P Version: In accordance with IEEE Standard 488-1978 implemented as SH1, AH1, T5, L3, SR1, RL1, PP1, DC1, DT1, and C0; Non-P Version (Plotter Output): Implemented as SH1, AH0, T3, L0, SR0, RL0, PP0, DC0, DT0, and C0 }}
{{EndSpecs}}
{{EndSpecs}}


==Options==
</small>
'''Options'''
* Opt. 01: Add preselector for the 1.7 to 21 GHz band and limiter for 1st mixer below 1.8 GHz
* Opt. 01: Add preselector for the 1.7 to 21 GHz band and limiter for 1st mixer below 1.8 GHz
* Opt. 07: 75Ω dBmV input and calibration in addition to 50Ω dBm input and calibration; Includes BNC male to female adapter connector, 42 inch BNC to BNC connector 75Ω coax cable
* Opt. 07: 75 Ω dBmV input and calibration in addition to 50Ω dBm input and calibration; Includes BNC male to female adapter connector, 42 inch BNC to BNC connector 75Ω coax cable
* Opt. 21: High Performance 18 to 40 GHz Waveguide Mixer Set includes two mixers (18 to 26.5 GHz, and 26.5 GHz to 40 GHz)
* Opt. 21: High Performance 18 to 40 GHz Waveguide Mixer Set includes two mixers (18 to 26.5 GHz, and 26.5 GHz to 40 GHz)
* Opt. 22: High Performance 18 to 60 GHz Waveguide Mixer Set includes three mixers (18 to 26.5 GHz, 26.5 GHz to 40 GHz, and 40 GHz to 60 GHz)
* Opt. 22: High Performance 18 to 60 GHz Waveguide Mixer Set includes three mixers (18 to 26.5 GHz, 26.5 GHz to 40 GHz, and 40 GHz to 60 GHz)
Line 66: Line 57:
* Opt. 42: Replaces MARKER/VIDEO input port on the rear panel with a 110 MHz IF output port that provides a 3 dB signal bandwidth ≥4.5 MHz
* Opt. 42: Replaces MARKER/VIDEO input port on the rear panel with a 110 MHz IF output port that provides a 3 dB signal bandwidth ≥4.5 MHz
* Opt. 45: MATE/CIIL language
* Opt. 45: MATE/CIIL language
* Opt. 52: North American 220V configuration with standard power cord.  Fuses are replaced with 2 A slo-blo