186
edits
No edit summary |
m (→Power Supply) |
||
Line 21: | Line 21: | ||
==Power Supply== | ==Power Supply== | ||
The 282 internally is supplied with ±10 V stabilized with Zener diodes. This allows the 282 to be compatible with the different negative supply voltages being present on the B pin of the [[Probe_power|probe power connector]] ranging from -12.2 V (3S1) to -25 V (4S1). | The 282 internally is supplied with ±10 V stabilized with Zener diodes. This allows the 282 to be compatible with the different negative supply voltages being present on the B pin of the [[Probe_power|probe power connector]] ranging from -12.2 V (3S1) to -25 V (4S1). | ||
===Compatible probe power=== | Positive supply is from +100 V. | ||
===Compatible probe power sampling plug ins=== | |||
* [[1S1]] | * [[1S1]] | ||
* [[3S1]] | * [[3S1]] | ||
Line 27: | Line 28: | ||
* [[4S1]] | * [[4S1]] | ||
* [[4S2]] | * [[4S2]] | ||
The 282 MOD 125D (015-0146-00) is a modified version which is supplied by a [[015-0073-00]] ±12 V power supply. | |||
Using a 015-0147-00 tee connector, two 282 MOD 125D units may be supplied. | |||
==Pictures== | ==Pictures== |
edits