3066: Difference between revisions

432 bytes removed ,  26 December 2022
m
no edit summary
No edit summary
mNo edit summary
 
(5 intermediate revisions by the same user not shown)
Line 9: Line 9:
|discontinued=(?)  
|discontinued=(?)  
|manuals=
|manuals=
* [[Media:Tek 3086 3066 071050101.pdf| Sony-Tek 3066_3086 User Manual (PDF)]]
* [[Media:071-0501-01.pdf| Sony-Tek 3066/3086 User Manual]]
* [[Media:071-0502-01_Sony-Tek_3066_3086_Programmer Manual.pdf| Sony-Tek 3066_3086 Programmer Manual (PDF)]]
* [[Media:071-0502-01.pdf| Sony-Tek 3066/3086 Programmer Manual]]
* [[Media:Tektronix_3066_3086_Catalog_Datasheet.pdf| Tektronix 3066_3086 Catalog Datasheet (PDF)]]
* [[Media:075-0535-00.pdf|3066/3086 Software Upgrade Kit V2.25]]
* [[Media:Tektronix_3066_3086_Catalog_Datasheet.pdf| Tektronix 3066_3086 Catalog Datasheet]]
}}
}}
The '''Sony/Tektronix 3066''' is a portable real time spectrum analyzer with a frequency range of 10 MHz to 3 GHz.  This spectrum analyzer is equipped with a 3 GHz down converter for analyzing radio frequency (RF) signals and allows seamless capture of frequency spectra with spans of up to 30 MHz.  This allows the spectrum of burst signals, such as those from GSM, IS-136, PDC or partial rate CDMA mobile stations that are captured and examined.
The '''Sony/Tektronix 3066''' is a portable real time spectrum analyzer with a frequency range of 10 MHz to 3 GHz.  This spectrum analyzer is equipped with a 3 GHz down converter for analyzing radio frequency (RF) signals and allows seamless capture of frequency spectra with spans of up to 30 MHz.  This allows the spectrum of burst signals, such as those from GSM, IS-136, PDC or partial rate CDMA mobile stations to be captured and examined.


The 3066 can obtain time domain and frequency domain data simultaneously through a new architecture which allows capturing a block of frequencies all at once.  Because this instrument samples these full frames constantly (rather than waiting for each discrete frequency step to be measured), the signal can come or go as it pleases and the real-time spectrum analyzer will detect the change instantly.
The 3066 can obtain time domain and frequency domain data simultaneously through an architecture which allows capturing a block of frequencies all at once.  Because this instrument samples these full frames constantly (rather than waiting for each discrete frequency step to be measured), the signal can come or go as it pleases and the real-time spectrum analyzer will detect the change instantly.


A frequency mask trigger allows capture of randomly occurring or infrequent signals such as intermittent spurious emissions, as well as, the capture of “burst-on” periods, thus maximizing the number of bursts that can be captured in memory for subsequent spectral, time, or modulation analysis.  The user can graphically define the frequency trigger mask; this allows the trigger condition to be generated by a particular event in the frequency domain.
A frequency mask trigger allows capture of randomly occurring or infrequent signals such as intermittent spurious emissions, as well as, the capture of “burst-on” periods, thus maximizing the number of bursts that can be captured in memory for subsequent spectral, time, or modulation analysis.  The user can graphically define the frequency trigger mask; this allows the trigger condition to be generated by a particular event in the frequency domain.
Line 28: Line 29:


{{BeginSpecs}}
{{BeginSpecs}}
{{Spec | Frequency Range | RF Mode: 10 MHz to 3 GHz; Baseband Mode: DC to 10 MHz }}
{{Spec | Frequency | RF Mode: 10 MHz to 3 GHz; Baseband Mode: DC to 10 MHz }}
{{Spec | Frequency Span Range | RF Mode: 100 Hz to 3 GHz; Baseband Mode: 100 Hz to 6 MHz }}
{{Spec | Frequency Span | RF Mode: 100 Hz to 3 GHz; Baseband Mode: 100 Hz to 6 MHz }}
{{Spec | RF Input impedance | 50 Ω }}
{{Spec | RF Input impedance | 50 Ω }}
{{Spec | Maximum Safe Input Power | +30 dBm }}
{{Spec | Maximum Safe Input Power | +30 dBm }}
{{Spec | Input Modes | RF, Baseband }}
{{Spec | Reference Level | RF Mode: –50 dBm to +30 dBm; Baseband Mode: –30 dBm to +30 dBm }}
{{Spec | Attenuator Range (used in Baseband Mode only) | (Spec missing from datasheet) }}
{{Spec | Reference Level Range | RF Mode: -50 dBm to +30 dBm; Baseband Mode: -30 dBm to +30 dBm }}
{{Spec | Spectral Frame Update Interval | 1024-point: 6400 ms to 80 µs; 256-point: 1600 ms to 20 µs }}
{{Spec | Spectral Frame Update Interval | 1024-point: 6400 ms to 80 µs; 256-point: 1600 ms to 20 µs }}
{{Spec | Triggering Modes | Auto, Normal [RF (span ≤ 6MHz) and Baseband Input, Quick, Delayed, Interval, Quick-interval, and Timeout }}
{{Spec | Triggering Modes | Auto, Normal [RF (span ≤ 6MHz) and Baseband Input, Quick, Delayed, Interval, Quick-interval, and Timeout }}
{{Spec | Trigger Source | Internals, External }}
{{Spec | Trigger Source | Internals, External }}
{{Spec | Frequency Trigger Mask | Resolution: 1 bin; Level Range: 0 dBfs to -79 dBfs }}
{{Spec | Frequency Trigger Mask | Resolution: 1 bin; Level Range: 0 dBfs to –79 dBfs }}
{{Spec | Time Trigger Mask | Resolution: 1 data point; Level Range: 0 dBfs to -40 dBfs }}
{{Spec | Time Trigger Mask | Resolution: 1 data point; Level Range: 0 dBfs to –40 dBfs }}
{{Spec | Marker | Types: Normal, Delta, Band-Power; Search Function: Peak Right, Peak Left, Maximum }}
{{Spec | Marker | Types: Normal, Delta, Band-Power; Search Function: Peak Right, Peak Left, Maximum }}
{{Spec | Measurement Function | Noise Power, Power with Band, C/N, Adjacent Channel Power, Occupied Bandwidth }}
{{Spec | Measurement Function | Noise Power, Power with Band, C/N, Adjacent Channel Power, Occupied Bandwidth }}
{{Spec | Digital Zoom | Zoom Ratio: 2 to 1000; Max Span in Zoom Mode: 5 MHz (RF, Baseband) }}
{{Spec | Digital Zoom | Zoom Ratio: 2 to 1000; Max Span in Zoom Mode: 5 MHz (RF, Baseband) }}
{{Spec | Input Equivalent Noise | RF: −140 dBm/Hz; Baseband: -150 dBm/Hz }}
{{Spec | Input Equivalent Noise | RF: –140 dBm/Hz; Baseband: –150 dBm/Hz }}
{{Spec | Spurious Free Dynamic Range | RF: 80 dB at 50 kHz span; 65 db at 1/2/5 MHz span; Baseband: 85 db at 50 kHz; 70 db at 1/2/5 MHz span }}
{{Spec | Spurious Free Dynamic Range | RF: 80 dB at 50 kHz span; 65 db at 1/2/5 MHz span; Baseband: 85 db at 50 kHz; 70 db at 1/2/5 MHz span }}
{{Spec | Included Accessories | User Manual, U.S. Power Cord }}
{{Spec | Weight | 24 kg (53 lbs) }}
{{Spec | Weight | 24 kg (53 lbs) }}
{{Spec | Power | 100 − 240 V<sub>AC</sub>, 47 − 66 Hz; 250 W max }}
{{Spec | Power | 100–240 V<sub>AC</sub>, 47–66 Hz; 250 W max }}
{{Spec | Operating Atmospherics | Temperatures: +5 °C to +40 °C;  Humidity: 80 %; Altitude: Up to 3 km (10,000 ft) }}
{{EndSpecs}}
{{EndSpecs}}


==Options==
==Options==
* Opt. 15: IS-95 Code Domain power.
* Opt. 15: IS-95 Code Domain power
* Opt. 1S: Data capture software.
* Opt. 1S: Data capture software
* Opt. C3: Three years of calibration services.
* Opt. D1: Test Data
* Opt. C5: Five years of calibration services.
* Opt. D1: Test Data.
* Opt. D3: Test Data (requires Opt. C3)
* Opt. D3: Test Data (requires Opt. C3)
* Opt. R3: Three years of repair protection.
* Opt. R3: Three years of repair protection


==Recommended Accessories==
==Recommended Accessories==