3B5: Difference between revisions

3,246 bytes added ,  29 November 2023
no edit summary
No edit summary
No edit summary
 
(16 intermediate revisions by 3 users not shown)
Line 1: Line 1:
{{Plugin Sidebar 2 |
{{Plugin Sidebar
title=Tektronix 3B5 |
|manufacturer=Tektronix
summary=Automatic time base |
|series=560-series scopes
image=Tek 3b5 front.JPG |
|type=3B5
caption=Tektronix 3B5 front |
|summary=Automatic time base plug-in
introduced=1966 |
|image=Tek 3b5 front.jpeg
discontinued=1972 |
|caption=Tektronix 3B5 front
series=[[560-series scopes]] |
|introduced=1966
manuals=
|discontinued=1972
* [http://w140.com/3b5.pdf Tektronix 3B5 Manual (PDF)]
|designers=
* [http://w140.com/3b5.pdf Tektronix 3B5 Manual (DjVu)]
|manuals=
* [[Media:070-0538-00.pdf|Tektronix 3B5 Manual]] (OCR)
* [[Media:070-0538-00.djvu|Tektronix 3B5 Manual]] (DjVu)
* [[Media:Tek 3b5 fcp feb 1967.pdf|Tektronix 3B5 Factory Calibration Procedure, February 1967‎]]
* [[Media:Tek 3a5 3b5 ieee spectrum june 1966.pdf|Tek 3A5/3B5 ad in IEEE Spectrum, June 1966]]
}}
}}
The Tektronix 3B5 is a timebase plug-in for [[560-series scopes]].   
The '''Tektronix 3B5''' is a timebase plug-in for [[560-series scopes]].   
It can be remotely controlled and also has an automatic mode.


==Specifications==
It can be remotely controlled and also has an automatic "seek" mode. 
[[Category:Specifications needed]]''please add''
It is typically used with a [[3A5]] vertical plug-in.
 
{{MissingSpecs}}


==Links==
==Links==
* https://youtu.be/WSOOvTI2XMg
* [https://youtu.be/WSOOvTI2XMg Tektronix 3A5 and 3B5 Automatic Seeking Mode] @ YouTube
* [https://vintagetek.org/automatic-programmable-plug-ins/ Automatic / Programmable Plug-ins] @ vintagetek.org
{{Documents|Link=3B5}}
 
==Seek Mode==
When the 3B5 is put into seek mode, it automatically finds a good sweep speed.
The criterion for a sweep speed being good is that it is the slowest sweep such that a second trigger event does not occur before the sweep has progressed beyond a set time window.
The time window begins at the start of the sweep and typically extends for three divisions. The "CYCLES/SWEEP" potentiometer controls when the time window ends.
 
The sweep seek state machine starts with the sweep reset and the sweep speed at its slowest.
The trigger is armed and if a signal is present, the sweep begins.
If a second trigger event occurs during the time window, the sweep is considered too slow.
In that case, the sweep speed is incremented to the next faster setting.
If the sweep gets beyond the window without a second trigger event occurring,
the sweep is considered good, and the sweep seek state machine stops.
When the sweep seek state machine is stopped, the scope operates in normal mode, i.e., waiting for trigger, sweeping, resetting, and waiting for trigger in an endless loop.
 
For example, say the 3B5 window is three divisions and the input signal is a 1 kHz square wave, and rising edge triggering is selected.
The user engages SEEK mode.
# The sweep seek state machine sets the sweep speed to 5 sec/div. Three divisions at 5 sec/div is 15 seconds, so the time window begins at the rising edge event that caused the sweep to start, and ends 15 seconds after the that event. The second rising of the 1 kHz occurs after 1 ms, so it occurs within the time window. Therefore, the sweep speed is advanced to 2 sec/div.
# At 2 sec/div, the window is 6 seconds. 1 ms < 6 seconds; sweep speed is advanced to 1 sec/div.
# At 1 sec/div, the window is 3 seconds. 1 ms < 3 seconds; sweep speed is advanced to 0.5 sec/div.
# At 0.5 sec/div, the window is 1.5 seconds. 1 ms < 1.5 seconds; sweep speed is advanced to 0.2 sec/div.
# At 0.2 sec/div, the window is 0.6 seconds. 1 ms < 0.6 seconds; sweep speed is advanced to 0.1 sec/div.
# At 0.1 sec/div, the window is 0.3 seconds. 1 ms < 0.3 seconds; sweep speed is advanced to 50 ms/div.
# At 50 ms/div, the window is 150 ms. 1 ms < 150 ms; sweep speed is advanced to 20 ms/div.
# At 20 ms/div, the window is 60 ms. 1 ms < 60 ms; sweep speed is advanced to 10 ms/div.
# At 10 ms/div, the window is 30 ms. 1 ms < 30 ms; sweep speed is advanced to 5 ms/div.
# At 5 ms/div, the window is 15 ms. 1 ms < 15 ms; sweep speed is advanced to 2 ms/div.
# At 2 ms/div, the window is 6 ms. 1 ms < 6 ms; sweep speed is advanced to 1 ms/div.
# At 1 ms/div, the window is 3 ms. 1 ms < 3 ms; sweep speed is advanced to 0.5 ms/div.
# At 0.5 ms/div, the window is 1.5 ms. 1 ms < 1.5 ms; sweep speed is advanced to 0.2 ms/div.
# At 0.2 ms/div, the window is 0.6 ms. 1 ms > 0.6 ms; sweep speed stays at 0.2 ms/div.


==Pictures==
==Pictures==
<gallery>
<gallery>
File:Tek 3b5 front.JPG
Tek 3b5 front.JPG
File:Tek 3b5 right.JPG
Tek 3b5 right.JPG
File:Tek 3b5 left.JPG
Tek 3b5 left.JPG
Image:Tek 3b5.jpg
Tek 3b5.jpg
File:Tek 3b5 logic.JPG|Logic Board
Tek 3b5 logic.JPG|Logic Board
File:Tek 3b5 counter.JPG|Counter Board
Tek 3b5 counter.JPG|Counter Board
File:Tek 3b5 panel wiring.JPG|Panel Wiring
Tek 3b5 panel wiring.JPG|Panel Wiring
Image:3b5 1969 cat.jpg|3B5 description in 1969 catalog
3b5 1969 cat.jpg|3B5 description in 1969 catalog
Image:3b5 program port.gif|Programming port pinout.
3b5 program port.gif|Programming port pinout.
</gallery>
</gallery>
==Components==
{{Parts|3B5}}




[[Category:560 series plugins]]
[[Category:560 series plugins]]