3L5: Difference between revisions

From TekWiki
Jump to navigation Jump to search
m (→‎top: clean up, replaced: title=Tektronix → manufacturer=Tektronix |series=560-series scopes |type=, {{Plugin Sidebar 2 → {{Plugin Sidebar, series=560-series scopes → designers=)
Line 1: Line 1:
{{Plugin Sidebar 2 |
{{Plugin Sidebar |
title=Tektronix 3L5 |
manufacturer=Tektronix |series=560-series scopes |type= 3L5 |
summary=1 MHz Spectrum Analyzer |
summary=1 MHz Spectrum Analyzer |
image=Tek_3L5_LateSN.jpeg |
image=Tek_3L5_LateSN.jpeg |
caption=Tektronix 3L5 Spectrum Analyzer |
caption=Tektronix 3L5 Spectrum Analyzer |
series=[[560-series scopes]] |
designers= |
introduced=1967 |
introduced=1967 |
discontinued=(?) |
discontinued=(?) |
Line 11: Line 11:
* [[Media:Tek 3l5 fcp aug 1967.pdf|Tektronix 3L5 Factory Calibration Procedure, August 1967 (PDF)]]
* [[Media:Tek 3l5 fcp aug 1967.pdf|Tektronix 3L5 Factory Calibration Procedure, August 1967 (PDF)]]
}}
}}
The '''Tektronix 3L5''' is a 50 Hz — 1 MHz spectrum analyzer plug-in for [[560-series scopes]].  
The '''Tektronix 3L5''' is a 50 Hz — 1 MHz spectrum analyzer plug-in for [[560-series scopes]].  
   
   
It is very similar to the [[1L5]] and can be used to measure the spectrum of signals.   
It is very similar to the [[1L5]] and can be used to measure the spectrum of signals.   
In conjunction with the [[015-0107-00]] "Swept Frequency Generator" (tracking generator),  
 
the 3L5 can also be used to make scalar frequency response measurements.
In conjunction with the [[015-0107-00]] "Swept Frequency Generator" (tracking generator), the 3L5 can also be used to make scalar frequency response measurements.
A video filter switch was added to the later SNs (1971 Catalog). 3L5 is based on the swept-frontend design, where the first local Oscillator is swept for the spectrum scan.  
A video filter switch was added to the later SNs (1971 Catalog).  
The 3L5 is based on the swept-frontend design, where the first local Oscillator is swept for the spectrum scan.  
It is a full semiconductor design except for the final output amplifier, which uses a [[8416]] vacuum tube.  
It is a full semiconductor design except for the final output amplifier, which uses a [[8416]] vacuum tube.  



Revision as of 12:34, 14 August 2021

Tektronix 3L5
1 MHz Spectrum Analyzer
Tektronix 3L5 Spectrum Analyzer

Compatible with 560-series scopes

Produced from 1967 to (?)

Manuals
Manuals – Specifications – Links – Pictures

The Tektronix 3L5 is a 50 Hz — 1 MHz spectrum analyzer plug-in for 560-series scopes.

It is very similar to the 1L5 and can be used to measure the spectrum of signals.

In conjunction with the 015-0107-00 "Swept Frequency Generator" (tracking generator), the 3L5 can also be used to make scalar frequency response measurements. A video filter switch was added to the later SNs (1971 Catalog). The 3L5 is based on the swept-frontend design, where the first local Oscillator is swept for the spectrum scan. It is a full semiconductor design except for the final output amplifier, which uses a 8416 vacuum tube.

75 Ω Version

There is also a 75 Ω version of the 3L5. Its input is on the rear, via a coaxial connector. A lever on the front panel switches between two frequency ranges:

  • 10 kHz - 1 MHz
  • 18.010 MHz - 19 MHz

Timebase Support

3L5 requires a timebase plug-in in the horizontal compartment to operate. Timebase plug-in units with serial no listed and below require modification 040-0413-00 to provide the sweep signal to the 3L5 (To pin 18 of the plug-in connector).

Time Base SN#
2B67 15180
3B1 4040
3B3 4270
3B4 740

Key Specifications

}
Center Frequency Range 50 Hz to 990 kHz
Dispersion Range 10 Hz to 100 kHz
Input Impedance ≈ 1 MΩ // 30 pF
Input Voltage Max. 300 V (DC + peak AC)
Vertical Resolution Video - .1 v/div to 100 v/div, LIN - .001 V to 2V RMS
Internal Cal Signal 5 kHz ±1%
First LO Out ≥1 MHz (Sweep), ≥1 Vp-p into ≥1 kΩ
Recorder Out 5 mV to 15 mV into 600Ω
Weight ≈6 pounds

Pictures

1 MΩ version

75 Ω version