465: Difference between revisions

8,292 bytes added ,  30 December 2023
no edit summary
m (-)
No edit summary
 
(109 intermediate revisions by 13 users not shown)
Line 1: Line 1:
{{Oscilloscope Sidebar |
{{Oscilloscope Sidebar
title=Tektronix 465 |
|manufacturer=Tektronix
summary=Portable 100 MHz dual-trace scope |
|series=400-series scopes
image=tek-465-manual.jpg |
|model=465  
caption=Tektronix 465 front |
|summary=Portable 100 MHz dual-trace scope  
introduced=1973 |
|image=Tek 465 trace.jpg
discontinued=1983 |
|caption=Tektronix 465 Front
manuals=
|introduced=1972
* [http://w140.com/mmm/tek-465-late.pdf Tektronix 465 Manual (PDF)]
|discontinued=1983  
* [http://w140.com/465b_trig2.pdf Tektronix 465B Trigger Generator Schematic (PDF)]
|designers=Leon Orchard;Luis Navarro;Bob Shand;Jim Hinze;Frank Dewater;Pete Janowitz;Dave Laib;Al Schamel;Bert tenKate;Ken Holland;Bill Mark;George Ermini;Dennis Braatz
* [http://elektrotanya.com/tektronix_465_oscilloscope_full_sm.pdf/download.html Tektronix 465 Manual (PDF) (better scan)]
|manuals=
'''465'''
* [[Media:070-2038-00.pdf      | 465 + DM44 Operator                        ]] (OCR, 4M)<br /><small>''[[Media:070-2038-00_1976.pdf  | Alternate Copy  ]]''
</small>
* [[Media:070-1330-00.pdf      | 465 Service, 070-1330-00 early version      ]] (OCR, 53M)<br /><small>''[[Media:070-1330-00 (2).pdf  | Alternate Copy  ]] (OCR, 3M)<br />[[Media:TEK 465LOWSN 070-1330-00 REV1.pdf|465 Service, 070-1330-00 Low SN Rev.1]] (OCR, 27M)''</small>
* [[Media:070-1861-00.pdf      | 465 Service B250000+                        ]] (OCR, 44M)
* [[Media:070-1861-00_C.pdf    | 465 Service B250000+                        ]] (Color OCR, 58M)
* [[Media:070-1861-01.pdf      | 465 Service B250000 and up, latest revision ]]
* [[Media:070-2191-00.pdf       | 465 Option 5 Supplement                    ]]
 
'''465B'''
* [[Media:070-2756-00.pdf                            | 465B + DM44 Operator -00, with Option 05  ]] (OCR)
* [[Media:070-2756-01.pdf                            | 465B + DM44 Operator -01, with Option 05  ]]
* [[Media:070-2757-00.pdf                            | 465B Service Manual                       ]] (200MB)
* [[Media:070-4273-00.pdf                            | 465B Service Manual, B060000+              ]]  ''please add''
* [[Media:465b_trig2.pdf                              | Tektronix 465B Trigger Generator Schematic ]]
* [[Media:465b_schematic.pdf                         | Tektronix 465B Trigger Generator Schematic ]] (bad-OCR)
* [[Media:465B_Vertical_Mode_Switch_(4)_Schematic.pdf | 465B Vertical Mode Switch Schematic <4>    ]]
<small>
* [[Media:070-2757-00-M38666.jpg                      | Service Manual Change Information M38666  ]]
* [[Media:070-2757-00-M40219.jpg                      | Service Manual Change Information M40219  ]]
</small>
 
<small>
'''Modifications'''
* [https://hakanh.com/dl/docs/kitinstructions/040-0968-01.pdf 040-0968-01 ]: 465 Opt.7 External DC Operation (1982)
* [https://hakanh.com/dl/docs/kitinstructions/040-0814-02.pdf 040-0814-02 ]: Installation of [[DM44]] on 465 B052300 - B251074
* [https://hakanh.com/dl/docs/kitinstructions/040-0815-01.pdf 040-0815-01 ]: Installation of [[DM44]] on 465 B251075 & up
* [https://hakanh.com/dl/docs/kitinstructions/040-0944-00.pdf 040-0944-00 ]: Installation of [[DM44]] on 465B
* [https://hakanh.com/dl/docs/kitinstructions/050-1627-00.pdf 050-1627-00 ]: S1150 (Time/cm switch) replacement
* [[Media:061-1904-00.pdf                                                  | 465 DIGITAL STORAGE Mod UC                    ]]
* [[Media:061-1057-00.pdf                                                  | 465 Mod XB                                    ]]
* [[Media:050-1558-00.pdf                                                  | 465B Modification: U3165 Replacement          ]]
* [[050-0674-00                                                            | Handle Replacement Modification Kit            ]]
* [[Media:Tek 465 mod QB transition counter.pdf                            | 465 Mod QB Transition Counter                  ]]
</small>
 
====History====
* [[Media:Tek 465 and 475 marketing sales release.pdf  |  Tektronix 465 and 475 Marketing Sales Release  ]]
}}
}}
:''Note: The [[465M|Tektronix 465M scope]] has its own page.''
The '''Tektronix 465''' is a portable 100 MHz dual-trace oscilloscope with dual time-bases, [[introduced in 1972|introduced in November 1972]].
It is all solid-state except for the CRT.  The 465 was very popular and Tek made them for quite a few years.  According to microfiche records, 37 variations of the 465 were produced.
[[Bill Turner|There was no 465A]] but a 465B (int. 1980) with the same base specs but improved performance.
The [[475]] is a 200 MHz sister model. See also [[465M]].
The optional [[DM44]] multimeter attaches to the top of the instrument.


The '''Tektronix 465''' is a portable 100 MHz dual-trace oscilloscope with dual time-bases. The 465 was very popular and Tek made them for quite a few years. It is all solid-state except for the CRT.  The 465 uses tunnel diodes with Tek part number 152-0125-00, which are equivalent to [[TD3A]].  
From [[Media:Tekscope 1972 V4 N5 Sep 1972.pdf | Tekscope Vol. 4 No. 5, 1972 ]]:
<blockquote>
Initial product planning and project coordination was provided by [[Leon Orchard]].  
The mechanical design team for the 465 and 475, headed by [[Bob Rossman]], was: [[Neal Broadbent]], [[Bob Leith]], [[Len McCracken]], [[Bob Smesrud]], [[Ilmars Smiltins]], and [[Bob Twigg]].
[[Ken Holland]] and [[Bill Mark]] provided the attenuator design while [[Bob Johnson]] designed the [[P6065]] and [[P6075]] probes. Low-voltage power supply for the 465/475 was by [[George Ermini]], and [[Dennis Braatz]] designed the high-voltage supply. [[Connie Wilson]] and [[Gary Nelson]] did the CRT development.  


The 465 uses [[155-0032-00]] chips (their -01 grade) as trigger amplifiers.
Electrical design team assisting [[R. Michael Johnson]] in development of the 465 was: [[Frank Dewater]], [[Pete Janowitz]], [[Dave Laib]], [[Al Schamel]], and [[Bert tenKate]].  
</blockquote>


There was no 465A but a 465B (int. 1980) with the same base specs but improved performance.
[[Bill Turner]] worked as a calibration technician for the 465 oscilloscope group.


The optional [[DM44]] multimeter attaches to the top of the instrument.
{{BeginSpecs}}
{{Spec | Bandwidth        | DC to 100 MHz on CH1 & CH2 for −15°C to +40°C and DC to 85 MHz from +40°C to +55°C }}
{{Spec | Risetime          | 3.5 ns for 0°C to +40°C and 4.2 ns from +40°C to +55°C }}
{{Spec | Input impedance  | 1 MΩ ±2% // 20 pF }}
{{Spec | Input voltage    | max. 500 V DC (250 V<sub>DC</sub> when DC coupled) + Peak AC or 500 V<sub>p-p</sub> AC at < 1 kHz }}
{{Spec | Trigger coupling  | DC, AC, LF Reject, HF Reject }}
{{Spec | Channel isolation | 100:1 at 25 MHz }}
{{Spec | Z-Axis input      | DC to 50 MHz; 5 V<sub>p-p</sub> signal causes noticeable modulation at normal intensity }}
{{Spec | Output signals    | CH1 Vertical, A & B +Gate }}
{{Spec | Calibrator        | ~1 kHz, 300 mV, square wave }}
{{Spec | CRT              | [[T4650]] ([[154-0676-00]]/[[154-0676-05]]/[[154-0676-10]]) tube, P31 [[phosphor]], 18.5 kV acceleration, 8 cm × 10 cm graticule }}
{{Spec | Power            | 110/115/120/220/230/240 V<sub>AC</sub> ±10%, selected via primary voltage selector and regulating range selector assembly, 48 Hz to 440 Hz; 75 W }}
{{EndSpecs}}


==Specifications==
==Options==
[[Category:Specifications needed]] ''please add''
<small>
{| class="wikitable"
|+ 465 Options
|-
! Opt !! Tek catalogue name !! Description
|-
| 4  || EMI Environmental  || Adds filter circuits and Faraday mesh+ground contact spring in place of acrylic implosion window.
|-
| 5  || TV Sync Separator  || This option has a separate service manual.
|-
| 7  || EXT DC Operation  || DC Power Input. Adds rear socket, power selector switches and inverter module. Not available with DM43 or DM40.
|-
| 78  || P11 Phosphor      || Replaces P31 phosphor 154-0676-10 with P11 version 154-0676-14.
|}
</small>


==Links==
==Links==
* [https://lazyelectrons.wordpress.com/2017/10/30/tektronix-465-repair/          Rajesh's Tek 465 Repair ]
* [https://www.youtube.com/watch?v=I6ODi7qSpYg                                    Jim Williams repairs Tom Osborne's Tektronix 465B oscilloscope] (YouTube)
* [https://www.youtube.com/watch?v=81UA49dOFa4                                    Another successful 465 repair, shorted tantalum] (YouTube)
* [https://www.amplifier.cd/Test_Equipment/Tektronix/Tektronix_other/465.htm      Tek 465 page @ amplifier.cd]
* [http://lists.contesting.com/_amps/2012-06/msg00415.html                        465B differences ]
* [http://dangerousprototypes.com/2012/03/19/tektronix-465-oscilloscope-teardown/ Tek 465 "teardown" ]
* [https://groups.io/g/TekScopes/files/Replacing%20Electrolytic%20Filter%20Capacitors%20in%20a%20Tektronix%20465.pdf Replacing Electrolytic Filter Capacitors in a Tektronix 465]
* [https://www.youtube.com/watch?v=cnoWBIZUKHg                                    Power Supply and Tube Calibration] by Zenwizard Studios @ YouTube
* [https://www.youtube.com/watch?v=icGTBV1ZcUU                                    Vertical Amplifier Calibration (Full)] by Zenwizard Studios @ YouTube
* [https://www.youtube.com/watch?v=0g4dvpv3RBI                                    Trigger and Timebase Calibration (Full)] by Zenwizard Studios @ YouTube
* [https://www.youtube.com/watch?v=XqiMlfYoNP8                                    Extensive Board Removal (All but Main board)] by Zenwizard Studios @ YouTube
* [https://www.youtube.com/watch?v=AydDpgdCrFU                                    465 Mod UC ] by vintageTek Museum @ YouTube
* [https://www.youtube.com/watch?v=xe0uofu9lTc                                    Tektronix 465 Repair (Horz sweep Issues)] by Zenwizard Studios @ YouTube
{{Documents|Link=465}}
{{Documents|Link=465B}}
==Prices==
{| class="wikitable"
|-
! Year
! 1973
! 1976
! 1980 (B)
! 1982 (B)
! 1983
|-
! Catalog Price
| $1,725
| $2,095
| $2,600
| $2,995
|
|-
! In 2023 Dollars
| $12,000
| $11,300
| $9,700
| $9,600
|
|}
==Internals==
The 465 uses tunnel diodes with Tek part number [[152-0125-00]], which are equivalent to [[TD3A]], and [[155-0032-00]] chips (their -01 grade) as trigger amplifiers.


* [http://www.youtube.com/watch?v=I6ODi7qSpYg Jim Williams repairs Tom Osborne's Tektronix 465B oscilloscope] (YouTube)
==Common Problems==
* [http://www.spurtikus.de/basteln/repair/tek465/index.html Repairing a 465 (power supply, z axis amplifier, vertical pre amplifier issues)] - nice internal photos
* See [[465/Repairs]]
* [http://www.amplifier.cd/Test_Equipment/Tektronix/Tektronix_other/465.htm Tek 465 page @ amplifier.cd]
* [http://lists.contesting.com/_amps/2012-06/msg00415.html 465B differences]


==Pictures==
==Pictures==
[[Category:Image needed]]
===465===
<gallery>
Tek-465-front.jpg
Tek-465-back.jpg
Tek 465 trace.jpg
Tek 465 front2.jpg
Tek 465 front right.jpg
Tek-465-int1.jpg
Tek-465-int2.jpg
Tek-465-int3.jpg
Tek-465-int4.jpg
</gallery>
 
===465 OPT 4===
<gallery>
465_clear_vs_EMI_mesh.jpg
</gallery>
 
===465 OPT 7===
<gallery>
465-opt-7_20220807.jpg
</gallery>
 
===465 Mod UC===
<gallery>
Tek 465 mod uc front.jpg
Tek 465 mod uc internal.jpg
</gallery>
 
===465B===
<gallery>
Tek 465b trace.jpg
Tek 465b front.jpg
Tek 465b g1.jpg
Tek 465b g2.jpg
Tek 465b g3.jpg
Tek 465b g4.jpg
Tek 465b g6.jpg
Tek 465b g7.jpg
465B Interface Board 670-5996-13.jpg        |Interface board
465B Interface Board 670-5996-13 flash.jpg  |(camera flash used)
</gallery>


==Components==
{{Parts|465}}
{{Parts|465B}}


[[Category:400 series scopes]]
[[Category:400 series scopes]]
[[Category:Introduced in 1973]]