31,932
edits
No edit summary |
No edit summary |
||
(7 intermediate revisions by one other user not shown) | |||
Line 10: | Line 10: | ||
|designers=Gary Vance | |designers=Gary Vance | ||
|manuals= | |manuals= | ||
* [[Media:IM-502-1.pdf|502 (early) Instruction]] | '''502''' | ||
* [[Media:070-090.pdf|502 (late) Instruction]] | * [[Media:IM-502-1.pdf|502 (early) Instruction]] | ||
* [[Media:070-382.pdf|502A Instruction]] | * [[Media:070-090.pdf|502 (late) Instruction]] | ||
'''502A''' | |||
* [[Media:070-0382-02.pdf|502A/RM502A (late) Instruction)]] | * [[Media:070-382.pdf|502A Instruction]] | ||
* [[Media:Tek 502a fcp sn31k-up june 1969.pdf | Tektronix 502A sn 31,000-up Factory Calibration Procedure, June 1969 | * [[Media:070-0382-02.pdf|502A/RM502A (late) Instruction)]] | ||
* [[Media:Tek 502a cal outline.pdf]] | '''Calibration''' | ||
* [[Media:Tek 502a fcp sn31k-up june 1969.pdf | Tektronix 502A sn 31,000-up Factory Calibration Procedure, June 1969]] | |||
* [[Media:Tek 502a cal outline.pdf|502A Calibration Outline]] | |||
}} | }} | ||
The '''Tektronix 502''' is a dual-beam oscilloscope [[introduced in 1958]], followed by the 502A in 1963. There is also a rack-mount model, the RM502A. | The '''Tektronix 502''' is a dual-beam oscilloscope [[introduced in 1958]], followed by the 502A in 1963. There is also a rack-mount model, the RM502A. | ||
Line 37: | Line 39: | ||
{{spec | Weight | 23.6 kg (52lb) }} | {{spec | Weight | 23.6 kg (52lb) }} | ||
{{EndSpecs}} | {{EndSpecs}} | ||
==Links== | |||
{{Documents|Link=502}} | |||
{{Documents|Link=502A}} | |||
* [http://www.amplifier.cd/Test_Equipment/Tektronix/Tektronix_other/502A.htm Tektronix 502A] @ amplifier.cd (many internal pictures) | |||
* [https://youtu.be/0D-z6_M76Ls Tektronix 502A internals] @ youtube (German) | |||
==Prices== | ==Prices== | ||
Line 54: | Line 62: | ||
|align=right| $1,265 | |align=right| $1,265 | ||
|- | |- | ||
! | ! In 2023 Dollars | ||
|align=right| $ | |align=right| $8,700 | ||
|align=right| $ | |align=right| $8,500 | ||
|align=right| $ | |align=right| $10,500 | ||
|align=right| $ | |align=right| $9,600 | ||
|- | |- | ||
|} | |} | ||
Line 80: | Line 88: | ||
The 502 has a 123 °F (50.5 °C) [[thermal cutoff]] switch. | The 502 has a 123 °F (50.5 °C) [[thermal cutoff]] switch. | ||
==Pictures== | ==Pictures== | ||
Line 146: | Line 150: | ||
</gallery> | </gallery> | ||
===Applications=== | |||
<gallery> | |||
Tek 502A in Physiology Lab.jpg | Tek 502A in a Physiology lab | |||
</gallery> | |||
==Components== | |||
{{Parts|502}} | {{Parts|502}} | ||
{{Parts|502A}} | {{Parts|502A}} |