504: Difference between revisions

Jump to navigation Jump to search
87 bytes added ,  10 August 2021
no edit summary
No edit summary
No edit summary
(2 intermediate revisions by 2 users not shown)
Line 1: Line 1:
{{Oscilloscope Sidebar |
{{Oscilloscope Sidebar  
title=Tektronix 504 |
|manufacturer=Tektronix
summary=450 kHz scope |
|series=
image=Tek 504.JPG |
|model=504  
caption=Tektronix 504 |
|summary=450 kHz scope  
introduced=1960 |
|image=Tek 504.JPG  
discontinued=1973 |
|caption=Tektronix 504  
manuals=
|introduced=1960  
|discontinued=1973  
|designers=
|manuals=
* [http://bama.edebris.com/download/tek/504/tek%20504.v6.pdf Tektronix 504 Manual (PDF)]
* [http://bama.edebris.com/download/tek/504/tek%20504.v6.pdf Tektronix 504 Manual (PDF)]
}}
}}
The '''Tektronix 504''' is a monolithic oscilloscope
The '''Tektronix 504''' is a monolithic oscilloscope with a bandwidth of 450 kHz [[introduced in 1960]].  
with a bandwidth of 450 kHz [[introduced in 1960]].  


It was introduced at the same time as the [[503]],  
It was introduced at the same time as the [[503]], and is mechanically and electrically identical, other than the vertical amplifier.   
and is mechanically and electrically identical,  
other than the vertical amplifier.   


The 504 was also offered in a rack mount version, the RM504.
The 504 was also offered in a rack mount version, the RM504.
Line 22: Line 22:


==Internals==
==Internals==
The 503 incorporates two identical phase matched amplifiers  
The 503 incorporates two identical phase matched amplifiers with true differential inputs to support X-Y operation,  
with true differential inputs to support X-Y operation,  
whereas the 504 contains a simple ground referenced vertical amplifier.   
whereas the 504 contains a simple ground referenced vertical amplifier.   
Due to the low bandwidth and need to keep the selling price low,  
Due to the low bandwidth and need to keep the selling price low, neither the 503 or 504 include delay lines in the vertical signal path.
neither the 503 or 504 include delay lines in the vertical signal path.
Both scopes use the same CRTs, the [[T5030]].   
Both scopes use the same CRTs, the [[T5030]].   


Line 33: Line 31:
   
   
Triggering is done using a multivibrator made of a [[6DJ8]] tube.   
Triggering is done using a multivibrator made of a [[6DJ8]] tube.   
The vertical signal path has a [[6DJ8]] first stage,  
The vertical signal path has a [[6DJ8]] first stage, a BJT second stage, followed by the output stage.
a BJT second stage, followed by the the output stage.
The vertical and horizontal output stages use pairs of [[6CB6]] tubes.
The vertical and horizontal output stages use pairs of [[6CB6]] tubes.


Line 46: Line 43:
Rm504 white.jpg|RM504
Rm504 white.jpg|RM504
Tek rm504 trace.jpg|RM504 trace
Tek rm504 trace.jpg|RM504 trace
Tek rm504 internal1.jpg|RM504
Tek rm504 internal2.jpg|RM504
</gallery>
</gallery>


[[Category:Monolithic tube scopes]]
[[Category:Monolithic tube scopes]]