524: Difference between revisions

629 bytes added ,  8 December 2023
no edit summary
m (→‎top: clean up, replaced: {{Oscilloscope Sidebar → {{Oscilloscope Sidebar |manufacturer=Tektronix |designers=, title=Tektronix → model=)
No edit summary
 
(8 intermediate revisions by 2 users not shown)
Line 1: Line 1:
{{Oscilloscope Sidebar |manufacturer=Tektronix |designers= |
{{Oscilloscope Sidebar  
model= 524AD |
|manufacturer=Tektronix  
summary=TV waveform monitoring scope |
|series=  
image=Tek 524 trace.jpg |
|model=524AD  
caption=Tektronix 524AD |
|summary=TV waveform monitoring scope  
introduced=1953 |
|image=Tek 524 trace.jpg  
discontinued=(?) |
|caption=Tektronix 524AD  
manuals=
|introduced=1953  
* [[Media:Tek_524AD_OCRed.pdf|524AD Instruction Manual]] (2MB, PDF, OCR)
|discontinued=(?)  
* [[Media:Tek 524 cal procedure.pdf]]
|designers=Cliff Moulton
|manuals=
* [[Media:070-236.pdf|524AD Instruction Manual 070-236]]
* [[Media:Tek_524AD_OCRed.pdf|524AD Instruction Manual]] (OCR)
* [[Media:Tek 524 cal procedure.pdf|524 Calibration Procedure]]
* [[Media:Tek 524 calibration checklist.pdf|524 Calibration Checklist]]
}}
}}
The '''Tektronix 524AD''' is a monolithic oscilloscope [[introduced in 1953]] for monitoring television waveforms, designed by [[Cliff Moulton]].
The '''Tektronix 524AD''' is a monolithic oscilloscope [[introduced in 1953]] for monitoring television waveforms, designed by [[Cliff Moulton]].
Line 14: Line 19:
In a 1972 interview, [[Charlie Rhodes]] recalled:
In a 1972 interview, [[Charlie Rhodes]] recalled:
<blockquote>
<blockquote>
In 1953 Cliff Moulton re-designed the [[514]] for TV station needs. This became the 524, the first TV-oriented instrument. It looked like at market of 200 or so in those days, but wound up producing 10,000 of this model.
In 1953 Cliff Moulton re-designed the [[514]] for TV station needs.  
This became the 524, the first TV-oriented instrument.  
It looked like a market of 200 or so in those days, but wound up producing 10,000 of this model.
</blockquote>
</blockquote>


Interestingly, the 524 appears on page 31 of the [https://www.w140.com/RCA-Test-Equip-1966.pdf 1966 RCA Test Equipment Catalog].
Interestingly, the 524 appears on page 31 of the [[Media:RCA-Test-Equip-1966.pdf|1966 RCA Test Equipment Catalog]].


{{MissingSpecs}}
{{BeginSpecs}}
{{Spec | Bandwidth  | DC to 10 MHz @ ≥150 mV/div; with preamp, 2 Hz to 10 MHz down to 15 mV/div }}
{{Spec | Rise time | 40 ns }}
{{Spec | Deflection | variable from 15 mV/div to 50 V/div }}
{{Spec | Input | 1 MΩ // 45 pF; 10 MΩ // 15 pF with [[P510A]] ×10 probe }}
{{Spec | Sweep | 100 ns/div to 10 ms/div, ×3 and ×10 magnifier }}
{{Spec | Time markers | 1 μs, 100 ns, 50 ns, 318 ns, 1.59 μs (200 or 40 markers per TV line) }}
{{Spec | CRT | [[5ABP1]] (P1 [[phosphor]]) standard, P7 and P11 optional; 4 kV total acceleration (−1.5 kV/+2.5 kV) }}
{{Spec | Power | 500 W }}
{{Spec | Weight | 27.7 kg / 61 lbs }}
{{EndSpecs}}


The 524 weighs 61 pounds, uses 500 watts, and has a [[thermal cutoff]].  It uses [[selenium rectifiers]] in the low-voltage  
It uses [[selenium rectifiers]] in the low-voltage power supply.   
power supply.  It has a total of 4 kV CRT beam acceleration,
 
−1.5 kV on the cathode and +2.5 kV on the anode. 
The 524AD has a 56°C/133°F [[thermal cutoff]].
It normally came with a [[5ABP1]] CRT which has P1 [[phosphor]],
but P7 and P11 phosphors were also available.


==Links==
==Links==
Line 33: Line 48:
The vertical signal path of the 524 is similar to that of the [[514]].   
The vertical signal path of the 524 is similar to that of the [[514]].   
They have similar front-ends and similar [[distributed amplifier|distributed vertical output amplifiers]].
They have similar front-ends and similar [[distributed amplifier|distributed vertical output amplifiers]].
The vertical amplifier has a three-stage [[distributed amplifier]] section (6×[[6AG7]]).


The video trigger circuitry present in the 524 distinguish it from the 514.
The video trigger circuitry present in the 524 distinguish it from the 514.
Just before the L-C [[delay line]] in the vertical signal path, there is a
Just before the L-C [[delay line]] in the vertical signal path, there is a cathode follower, V15A, that serves as the trigger pickoff buffer.
cathode follower, V15A, that serves as the trigger pickoff buffer.
The resulting trigger signal goes to a video sync separator circuit.
The resulting trigger signal goes to a video sync separator circuit.
Here, the there is clamping and amplification and,  
Here, the there is clamping and amplification and, most importantly, a non-retriggerable multivibrator.   
most importantly, a non-retriggerable multivibrator.   
The multivibrator is triggered by the vertical sync of the NTSC waveform.
The multivibrator is triggered by the vertical sync of the NTSC waveform.
After being triggered, it is not triggerable again for about about 25 ms, so it
After being triggered, it is not triggerable again for about about 25 ms, so it misses the vertical sync of the next interlaced field and instead triggers on the vertical sync of one following that.   
misses the vertical sync of the next interlaced field and instead triggers on  
So it consistently shows the "even" field or the "odd" field.   
the vertical sync of one following that.  So it consistently shows the "even" field
There is a switch that perturbs the multivibrator so it can be switched between even and odd fields.   
or the "odd" field.  There is a switch that perturbs the multivibrator so it can be
The video trigger circuit drives a conventional trigger circuit and sweep circuit similar to that of the 514.
switched between even and odd fields.  The video trigger circuit drives a  
conventional trigger circuit and sweep circuit similar to that of the 514.


The 524 uses a cylindrical style of ceramic terminal strip, which is less common than the straight style.
The 524 uses a cylindrical style of [[ceramic strips|ceramic terminal strip]], which is less common than the straight style.
The cylindrical style is also used in the [[C|Type C]], [[CA|Type CA]], and [[315]].
The cylindrical style is also used in the [[C|Type C]], [[CA|Type CA]], and [[315]].
* [https://w140.com/tek_524_cal_checklist.pdf Tektronix 524 Calibration Checklist (PDF)]


==Pictures==
==Pictures==
Line 84: Line 95:
Tek early 524ad 9.jpg
Tek early 524ad 9.jpg
</gallery>
</gallery>
==Components==
{{Parts|524}}


[[Category:Monolithic tube scopes]]
[[Category:Monolithic tube scopes]]
[[Category:TV waveform monitors]]
[[Category:TV waveform monitors]]