36,239
edits
(template, cat) |
No edit summary |
||
(8 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
{{Plugin Sidebar | {{Plugin Sidebar | | ||
manufacturer=Tektronix |series=5000-series scopes |type= 5B25N | | |||
summary= | | summary=20 MHz digitizer time base | | ||
image= | image=Tek-5b25-front-crop.jpg | | ||
caption= | | caption=Tektronix 5B25N front | | ||
designers= | | |||
introduced= | introduced=1981 | | ||
discontinued=1988 | | discontinued=1988 | | ||
manuals= | manuals= | ||
* [http://w140.com/tek_5b25n.pdf Tektronix 5B25N Service Manual (no schematics | * [[Media:070-2813-00.pdf|Tektronix 5B25N Service Manual (1982 revision, complete, with schematics)]] | ||
* [http://w140.com/tek_5b25n.pdf Tektronix 5B25N Service Manual (1986 revision, incomplete, no schematics)] | |||
[[Category:Manual needed]] | [[Category:Manual needed]] | ||
}} | }} | ||
The '''Tektronix 5B25N''' is a "digitizer time base" for the [[5223]] scope, i.e. a time base that also contains a sample clock generator. | |||
It will also operate in 5400-series mainframes as a generic time base. | |||
The 5B25N/5223 system uses real-time sampling at sweep rates of 0.1 ms/div or slower. | |||
At sweep rates of 50 us/div or faster, equivalent-time sampling is used. | |||
The 5B25N uses the [[155-0109-01]] trigger chip (U95). | |||
{{BeginSpecs}} | |||
{{Spec | Sweep | 200 ns/Div to 5 s/Div, 1—2—5 }} | |||
{{Spec | Triggering | > 0.4 Div or 50 mV to 1 MHz, > 0.6 Div or 200 mV to 20 MHz }} | |||
{{Spec | X-Y mode | 50 mV/Div, 180 ns rise time, 2 MHz bandwidth, 1 MΩ // 24 pF input }} | |||
{{Spec | Features | | |||
* × 10 magnifier | |||
* Pretrigger adjustment 0-100% | |||
}} | |||
{{EndSpecs}} | |||
==Pictures== | ==Pictures== | ||
<gallery> | <gallery> | ||
5B25NFront (1).jpg | |||
5B25NLeft.jpg | |||
5B25NRight.jpg | |||
</gallery> | </gallery> | ||
{{Custom ICs|5B25N}} | |||
[[Category:5000 series horizontal plugins]] | [[Category:5000 series horizontal plugins]] |